Wireless measurement of Sympathetic Nervous activity using planar nanoelectrode arrays

Aamer Mahmoud, Peng Sheng Chen, A. George Akingba

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

This paper reports on the use of arrays of nanoelectrodes as implantable sensors to wirelessly measure the activity of the Sympathetic Nervous System - Sympathetic Nervous Activity (SNA). SNA can be measured as a train of electrical pulses. Traditionally, SNA has been measured with wire electrodes. These measurements have not been easy because of poor signal-to-noise ratio (SNR). In the current work, we have successfully demonstrated improved SNR of SNA measurements achieved by the use of novel Planar Nanoelectrode Arrays (PNAs) in a chronic setting. The PNAs are placed on the left stellate ganglion (SG) via a thoracotomy. Nano scale features on the electrodes provide increased contact area with the nerve of interest (in this case the SG) thereby reducing the limiting (Johnson) noise. The PNAs were fabricated using standard CMOS compatible fabrication techniques on a high resistivity silicon substrate. After suitable wire-bonding and packaging, the PNAs were placed on the left stellate ganglion of a canine test subject. For adequate comparison, a standard set of wire electrodes were embedded on the same nerve in close proximity of the PNAs. Both the sensors were connected to a wireless transmitter (Model No. TR 70BB) powered with a rechargeable battery also placed within the canine test subject. The thoracotomy incision was repaired and the canine test subject allowed to recover before beginning SNA measurements. Our results showed that the PNAs consistently exhibit superior SNR of the measured SNA. Measurements have been successfully made up to three months after implantation of the electrodes and the SNR of the PNA has been consistently better than the wire electrodes. After one month the SNR of the PNA was 48.54 ± 2.71 dB vs. 17.88 ± 4.49 dB for the wire electrode (p < 0.001). At three months the SNR of the PNA was 48.57 ± 1.63 dB vs. 18.98 ± 2.38 dB for the wire electrode (p < 0.001).

Original languageEnglish
Title of host publicationProceedings of IEEE Sensors
DOIs
Publication statusPublished - 2012
Externally publishedYes
Event11th IEEE SENSORS 2012 Conference - Taipei, Taiwan, Province of China
Duration: 28 Oct 201231 Oct 2012

Other

Other11th IEEE SENSORS 2012 Conference
CountryTaiwan, Province of China
CityTaipei
Period28/10/1231/10/12

Fingerprint

Signal to noise ratio
Wire
Electrodes
Secondary batteries
Sensors
Neurology
Transmitters
Packaging
Fabrication
Silicon
Substrates

Keywords

  • Nervous system
  • Signal to noise ration (SNR)
  • SNA
  • Stellate ganglion
  • Sympathetic Nervous Activity

ASJC Scopus subject areas

  • Electrical and Electronic Engineering

Cite this

Wireless measurement of Sympathetic Nervous activity using planar nanoelectrode arrays. / Mahmoud, Aamer; Chen, Peng Sheng; Akingba, A. George.

Proceedings of IEEE Sensors. 2012. 6411485.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Mahmoud, A, Chen, PS & Akingba, AG 2012, Wireless measurement of Sympathetic Nervous activity using planar nanoelectrode arrays. in Proceedings of IEEE Sensors., 6411485, 11th IEEE SENSORS 2012 Conference, Taipei, Taiwan, Province of China, 28/10/12. https://doi.org/10.1109/ICSENS.2012.6411485
Mahmoud, Aamer ; Chen, Peng Sheng ; Akingba, A. George. / Wireless measurement of Sympathetic Nervous activity using planar nanoelectrode arrays. Proceedings of IEEE Sensors. 2012.
@inproceedings{bc120b82c84a49e0a820defda8b68f12,
title = "Wireless measurement of Sympathetic Nervous activity using planar nanoelectrode arrays",
abstract = "This paper reports on the use of arrays of nanoelectrodes as implantable sensors to wirelessly measure the activity of the Sympathetic Nervous System - Sympathetic Nervous Activity (SNA). SNA can be measured as a train of electrical pulses. Traditionally, SNA has been measured with wire electrodes. These measurements have not been easy because of poor signal-to-noise ratio (SNR). In the current work, we have successfully demonstrated improved SNR of SNA measurements achieved by the use of novel Planar Nanoelectrode Arrays (PNAs) in a chronic setting. The PNAs are placed on the left stellate ganglion (SG) via a thoracotomy. Nano scale features on the electrodes provide increased contact area with the nerve of interest (in this case the SG) thereby reducing the limiting (Johnson) noise. The PNAs were fabricated using standard CMOS compatible fabrication techniques on a high resistivity silicon substrate. After suitable wire-bonding and packaging, the PNAs were placed on the left stellate ganglion of a canine test subject. For adequate comparison, a standard set of wire electrodes were embedded on the same nerve in close proximity of the PNAs. Both the sensors were connected to a wireless transmitter (Model No. TR 70BB) powered with a rechargeable battery also placed within the canine test subject. The thoracotomy incision was repaired and the canine test subject allowed to recover before beginning SNA measurements. Our results showed that the PNAs consistently exhibit superior SNR of the measured SNA. Measurements have been successfully made up to three months after implantation of the electrodes and the SNR of the PNA has been consistently better than the wire electrodes. After one month the SNR of the PNA was 48.54 ± 2.71 dB vs. 17.88 ± 4.49 dB for the wire electrode (p < 0.001). At three months the SNR of the PNA was 48.57 ± 1.63 dB vs. 18.98 ± 2.38 dB for the wire electrode (p < 0.001).",
keywords = "Nervous system, Signal to noise ration (SNR), SNA, Stellate ganglion, Sympathetic Nervous Activity",
author = "Aamer Mahmoud and Chen, {Peng Sheng} and Akingba, {A. George}",
year = "2012",
doi = "10.1109/ICSENS.2012.6411485",
language = "English",
isbn = "9781457717659",
booktitle = "Proceedings of IEEE Sensors",

}

TY - GEN

T1 - Wireless measurement of Sympathetic Nervous activity using planar nanoelectrode arrays

AU - Mahmoud, Aamer

AU - Chen, Peng Sheng

AU - Akingba, A. George

PY - 2012

Y1 - 2012

N2 - This paper reports on the use of arrays of nanoelectrodes as implantable sensors to wirelessly measure the activity of the Sympathetic Nervous System - Sympathetic Nervous Activity (SNA). SNA can be measured as a train of electrical pulses. Traditionally, SNA has been measured with wire electrodes. These measurements have not been easy because of poor signal-to-noise ratio (SNR). In the current work, we have successfully demonstrated improved SNR of SNA measurements achieved by the use of novel Planar Nanoelectrode Arrays (PNAs) in a chronic setting. The PNAs are placed on the left stellate ganglion (SG) via a thoracotomy. Nano scale features on the electrodes provide increased contact area with the nerve of interest (in this case the SG) thereby reducing the limiting (Johnson) noise. The PNAs were fabricated using standard CMOS compatible fabrication techniques on a high resistivity silicon substrate. After suitable wire-bonding and packaging, the PNAs were placed on the left stellate ganglion of a canine test subject. For adequate comparison, a standard set of wire electrodes were embedded on the same nerve in close proximity of the PNAs. Both the sensors were connected to a wireless transmitter (Model No. TR 70BB) powered with a rechargeable battery also placed within the canine test subject. The thoracotomy incision was repaired and the canine test subject allowed to recover before beginning SNA measurements. Our results showed that the PNAs consistently exhibit superior SNR of the measured SNA. Measurements have been successfully made up to three months after implantation of the electrodes and the SNR of the PNA has been consistently better than the wire electrodes. After one month the SNR of the PNA was 48.54 ± 2.71 dB vs. 17.88 ± 4.49 dB for the wire electrode (p < 0.001). At three months the SNR of the PNA was 48.57 ± 1.63 dB vs. 18.98 ± 2.38 dB for the wire electrode (p < 0.001).

AB - This paper reports on the use of arrays of nanoelectrodes as implantable sensors to wirelessly measure the activity of the Sympathetic Nervous System - Sympathetic Nervous Activity (SNA). SNA can be measured as a train of electrical pulses. Traditionally, SNA has been measured with wire electrodes. These measurements have not been easy because of poor signal-to-noise ratio (SNR). In the current work, we have successfully demonstrated improved SNR of SNA measurements achieved by the use of novel Planar Nanoelectrode Arrays (PNAs) in a chronic setting. The PNAs are placed on the left stellate ganglion (SG) via a thoracotomy. Nano scale features on the electrodes provide increased contact area with the nerve of interest (in this case the SG) thereby reducing the limiting (Johnson) noise. The PNAs were fabricated using standard CMOS compatible fabrication techniques on a high resistivity silicon substrate. After suitable wire-bonding and packaging, the PNAs were placed on the left stellate ganglion of a canine test subject. For adequate comparison, a standard set of wire electrodes were embedded on the same nerve in close proximity of the PNAs. Both the sensors were connected to a wireless transmitter (Model No. TR 70BB) powered with a rechargeable battery also placed within the canine test subject. The thoracotomy incision was repaired and the canine test subject allowed to recover before beginning SNA measurements. Our results showed that the PNAs consistently exhibit superior SNR of the measured SNA. Measurements have been successfully made up to three months after implantation of the electrodes and the SNR of the PNA has been consistently better than the wire electrodes. After one month the SNR of the PNA was 48.54 ± 2.71 dB vs. 17.88 ± 4.49 dB for the wire electrode (p < 0.001). At three months the SNR of the PNA was 48.57 ± 1.63 dB vs. 18.98 ± 2.38 dB for the wire electrode (p < 0.001).

KW - Nervous system

KW - Signal to noise ration (SNR)

KW - SNA

KW - Stellate ganglion

KW - Sympathetic Nervous Activity

UR - http://www.scopus.com/inward/record.url?scp=84873955163&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84873955163&partnerID=8YFLogxK

U2 - 10.1109/ICSENS.2012.6411485

DO - 10.1109/ICSENS.2012.6411485

M3 - Conference contribution

SN - 9781457717659

BT - Proceedings of IEEE Sensors

ER -