Volumetric mass transfer coefficient in non-Newtonian fluids in spout fluid beds - Part 1

Mohammed Z. Anabtawi, N. Hilal, A. E. Al Muftah

Research output: Contribution to journalArticle

7 Citations (Scopus)

Abstract

The volumetric liquid-phase mass transfer coefficient, kLa, was determined by absorption of oxygen in air using six different carboxy-methyl cellulose (CMC) solutions with different rheological values in three phase spout-fluid beds operated continuously with respect to both gas and liquid. Three cylindrical columns of 7.4 cm, 11.4 cm, and 14.4 cm diameters were used. Gas velocity was varied between 0.00154-0.00563 m/s, liquid velocity between 0.0116-0.0387 m/s, surface tension between 0.00416-0.0189 N/m, static bed height between 6.0-10.8 cm, and spherical glass particles of 1.75 mm diameter were used as packing material. A single nozzle sparger of 1.0 cm diameter was used in the spouting line. The volumetric mass transfer coefficient was found to increase with gas velocity, liquid velocity, and static bed height and to decrease with the increase of the effective liquid viscosity of the CMC solution. A dimensionless correlation was developed and compared with those listed in the literature.

Original languageEnglish
Pages (from-to)759-764
Number of pages6
JournalChemical Engineering and Technology
Volume26
Issue number7
DOIs
Publication statusPublished - Jul 2003
Externally publishedYes

    Fingerprint

ASJC Scopus subject areas

  • Chemical Engineering (miscellaneous)
  • Environmental Science(all)
  • Polymers and Plastics

Cite this