Three-dimensional inline inspection for substrate warpage and ball grid array coplanarity using stereo vision

Takeshi Nakazawa, Ayman Samara

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

We present a method for full-field 3D measurement of substrate warpage and ball grid array coplanarity, which is suitable for inline back-end inspection and process monitoring. For evaluating the performance of the proposed system, the linearity between our system and a reference confocal microscope is studied by repeating measurements 35 times with a particular substrate sample (38 mm × 28.5 mm). The point-to-point correlation coefficient with 1σ between two methods is 0.968 ± 0.002, and the 2σ difference is 25.15 ± 0.20 μm for warpage measurement. 1σ repeatability of the substrate warpage is 4.2 μm. For BGA coplanarity inspection the bump level correlation coefficient is 0.957 ± 0.001 and the 2σ difference is 28.79 ± 0.14 μm. 1σ repeatability of BGA coplanarity is 3.7 μm. Data acquisition takes about 0.2 s for full field measurements.

Original languageEnglish
Pages (from-to)3101-3109
Number of pages9
JournalApplied Optics
Issue number14
DOIs
Publication statusPublished - 10 May 2014
Externally publishedYes

Fingerprint

warpage
coplanarity
balls
inspection
grids
substrate
correlation coefficients
linearity
data acquisition
microscopes
monitoring
method

ASJC Scopus subject areas

  • Atomic and Molecular Physics, and Optics

Cite this

Three-dimensional inline inspection for substrate warpage and ball grid array coplanarity using stereo vision. / Nakazawa, Takeshi; Samara, Ayman.

In: Applied Optics, No. 14, 10.05.2014, p. 3101-3109.

Research output: Contribution to journalArticle

@article{8b1189f530924cd08ded78926ba9934e,
title = "Three-dimensional inline inspection for substrate warpage and ball grid array coplanarity using stereo vision",
abstract = "We present a method for full-field 3D measurement of substrate warpage and ball grid array coplanarity, which is suitable for inline back-end inspection and process monitoring. For evaluating the performance of the proposed system, the linearity between our system and a reference confocal microscope is studied by repeating measurements 35 times with a particular substrate sample (38 mm × 28.5 mm). The point-to-point correlation coefficient with 1σ between two methods is 0.968 ± 0.002, and the 2σ difference is 25.15 ± 0.20 μm for warpage measurement. 1σ repeatability of the substrate warpage is 4.2 μm. For BGA coplanarity inspection the bump level correlation coefficient is 0.957 ± 0.001 and the 2σ difference is 28.79 ± 0.14 μm. 1σ repeatability of BGA coplanarity is 3.7 μm. Data acquisition takes about 0.2 s for full field measurements.",
author = "Takeshi Nakazawa and Ayman Samara",
year = "2014",
month = "5",
day = "10",
doi = "10.1364/AO.53.003101",
language = "English",
pages = "3101--3109",
journal = "JAPCA",
issn = "1073-161X",
publisher = "Taylor and Francis Ltd.",
number = "14",

}

TY - JOUR

T1 - Three-dimensional inline inspection for substrate warpage and ball grid array coplanarity using stereo vision

AU - Nakazawa, Takeshi

AU - Samara, Ayman

PY - 2014/5/10

Y1 - 2014/5/10

N2 - We present a method for full-field 3D measurement of substrate warpage and ball grid array coplanarity, which is suitable for inline back-end inspection and process monitoring. For evaluating the performance of the proposed system, the linearity between our system and a reference confocal microscope is studied by repeating measurements 35 times with a particular substrate sample (38 mm × 28.5 mm). The point-to-point correlation coefficient with 1σ between two methods is 0.968 ± 0.002, and the 2σ difference is 25.15 ± 0.20 μm for warpage measurement. 1σ repeatability of the substrate warpage is 4.2 μm. For BGA coplanarity inspection the bump level correlation coefficient is 0.957 ± 0.001 and the 2σ difference is 28.79 ± 0.14 μm. 1σ repeatability of BGA coplanarity is 3.7 μm. Data acquisition takes about 0.2 s for full field measurements.

AB - We present a method for full-field 3D measurement of substrate warpage and ball grid array coplanarity, which is suitable for inline back-end inspection and process monitoring. For evaluating the performance of the proposed system, the linearity between our system and a reference confocal microscope is studied by repeating measurements 35 times with a particular substrate sample (38 mm × 28.5 mm). The point-to-point correlation coefficient with 1σ between two methods is 0.968 ± 0.002, and the 2σ difference is 25.15 ± 0.20 μm for warpage measurement. 1σ repeatability of the substrate warpage is 4.2 μm. For BGA coplanarity inspection the bump level correlation coefficient is 0.957 ± 0.001 and the 2σ difference is 28.79 ± 0.14 μm. 1σ repeatability of BGA coplanarity is 3.7 μm. Data acquisition takes about 0.2 s for full field measurements.

UR - http://www.scopus.com/inward/record.url?scp=84942370543&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84942370543&partnerID=8YFLogxK

U2 - 10.1364/AO.53.003101

DO - 10.1364/AO.53.003101

M3 - Article

AN - SCOPUS:84942370543

SP - 3101

EP - 3109

JO - JAPCA

JF - JAPCA

SN - 1073-161X

IS - 14

ER -