Thermo-fluids provisioning of a high performance high density data center

Abdlmonem Beitelmal, Chandrakant D. Patel

Research output: Contribution to journalArticle

61 Citations (Scopus)

Abstract

Consolidation and dense aggregation of slim compute, storage and networking hardware has resulted in high power density data centers. The high power density resulting from current and future generations of servers necessitates detailed thermo-fluids analysis to provision the cooling resources in a given data center for reliable operation. The analysis must also predict the impact on the thermo-fluid distribution due to changes in hardware configuration and building infrastructure such as a sudden failure in data center cooling resources. The objective of the analysis is to assure availability of adequate cooling resources to match the heat load, which is typically non-uniformly distributed and characterized by high-localized power density. This study presents an analysis of an example modern data center with a view of the magnitude of temperature variation and impact of a failure. Initially, static provisioning for a given distribution of heat loads and cooling resources is achieved to produce a reference state. A perturbation in reference state is introduced to simulate a very plausible scenario-failure of a computer room air conditioning (CRAC) unit. The transient model shows the "redlining" of inlet temperature of systems in the area that is most influenced by the failed CRAC. In this example high-density data center, the time to reach unacceptable inlet temperature is less than 80 seconds based on an example temperature set point limit of 40°C (most of today's servers would require an inlet temperature below 35°C to operate). An effective approach to resolve this issue, if there is adequate capacity, is to migrate the compute workload to other available systems within the data center to reduce the inlet temperature to the servers to an acceptable level.

Original languageEnglish
Pages (from-to)227-238
Number of pages12
JournalDistributed and Parallel Databases
Volume21
Issue number2-3
DOIs
Publication statusPublished - 1 Jun 2007
Externally publishedYes

Fingerprint

Data Center
High Performance
Fluid
Fluids
Cooling
Resources
Servers
Server
Thermal load
Conditioning
Air conditioning
High Power
Temperature
Heat
Hardware
Limit Point
Consolidation
Networking
Point Sets
Workload

Keywords

  • CFD analysis of data center
  • Computer room cooling
  • Cooling
  • Cooling of data center
  • Data center
  • Exergy
  • Heat
  • Load migration
  • Provisioning of data centers
  • Smart cooling
  • Transient analysis of data center

ASJC Scopus subject areas

  • Information Systems
  • Theoretical Computer Science
  • Computational Theory and Mathematics

Cite this

Thermo-fluids provisioning of a high performance high density data center. / Beitelmal, Abdlmonem; Patel, Chandrakant D.

In: Distributed and Parallel Databases, Vol. 21, No. 2-3, 01.06.2007, p. 227-238.

Research output: Contribution to journalArticle

@article{0e4bcc27796e410d8fa3ba9f924015ba,
title = "Thermo-fluids provisioning of a high performance high density data center",
abstract = "Consolidation and dense aggregation of slim compute, storage and networking hardware has resulted in high power density data centers. The high power density resulting from current and future generations of servers necessitates detailed thermo-fluids analysis to provision the cooling resources in a given data center for reliable operation. The analysis must also predict the impact on the thermo-fluid distribution due to changes in hardware configuration and building infrastructure such as a sudden failure in data center cooling resources. The objective of the analysis is to assure availability of adequate cooling resources to match the heat load, which is typically non-uniformly distributed and characterized by high-localized power density. This study presents an analysis of an example modern data center with a view of the magnitude of temperature variation and impact of a failure. Initially, static provisioning for a given distribution of heat loads and cooling resources is achieved to produce a reference state. A perturbation in reference state is introduced to simulate a very plausible scenario-failure of a computer room air conditioning (CRAC) unit. The transient model shows the {"}redlining{"} of inlet temperature of systems in the area that is most influenced by the failed CRAC. In this example high-density data center, the time to reach unacceptable inlet temperature is less than 80 seconds based on an example temperature set point limit of 40°C (most of today's servers would require an inlet temperature below 35°C to operate). An effective approach to resolve this issue, if there is adequate capacity, is to migrate the compute workload to other available systems within the data center to reduce the inlet temperature to the servers to an acceptable level.",
keywords = "CFD analysis of data center, Computer room cooling, Cooling, Cooling of data center, Data center, Exergy, Heat, Load migration, Provisioning of data centers, Smart cooling, Transient analysis of data center",
author = "Abdlmonem Beitelmal and Patel, {Chandrakant D.}",
year = "2007",
month = "6",
day = "1",
doi = "10.1007/s10619-005-0413-0",
language = "English",
volume = "21",
pages = "227--238",
journal = "Distributed and Parallel Databases",
issn = "0926-8782",
publisher = "Springer Netherlands",
number = "2-3",

}

TY - JOUR

T1 - Thermo-fluids provisioning of a high performance high density data center

AU - Beitelmal, Abdlmonem

AU - Patel, Chandrakant D.

PY - 2007/6/1

Y1 - 2007/6/1

N2 - Consolidation and dense aggregation of slim compute, storage and networking hardware has resulted in high power density data centers. The high power density resulting from current and future generations of servers necessitates detailed thermo-fluids analysis to provision the cooling resources in a given data center for reliable operation. The analysis must also predict the impact on the thermo-fluid distribution due to changes in hardware configuration and building infrastructure such as a sudden failure in data center cooling resources. The objective of the analysis is to assure availability of adequate cooling resources to match the heat load, which is typically non-uniformly distributed and characterized by high-localized power density. This study presents an analysis of an example modern data center with a view of the magnitude of temperature variation and impact of a failure. Initially, static provisioning for a given distribution of heat loads and cooling resources is achieved to produce a reference state. A perturbation in reference state is introduced to simulate a very plausible scenario-failure of a computer room air conditioning (CRAC) unit. The transient model shows the "redlining" of inlet temperature of systems in the area that is most influenced by the failed CRAC. In this example high-density data center, the time to reach unacceptable inlet temperature is less than 80 seconds based on an example temperature set point limit of 40°C (most of today's servers would require an inlet temperature below 35°C to operate). An effective approach to resolve this issue, if there is adequate capacity, is to migrate the compute workload to other available systems within the data center to reduce the inlet temperature to the servers to an acceptable level.

AB - Consolidation and dense aggregation of slim compute, storage and networking hardware has resulted in high power density data centers. The high power density resulting from current and future generations of servers necessitates detailed thermo-fluids analysis to provision the cooling resources in a given data center for reliable operation. The analysis must also predict the impact on the thermo-fluid distribution due to changes in hardware configuration and building infrastructure such as a sudden failure in data center cooling resources. The objective of the analysis is to assure availability of adequate cooling resources to match the heat load, which is typically non-uniformly distributed and characterized by high-localized power density. This study presents an analysis of an example modern data center with a view of the magnitude of temperature variation and impact of a failure. Initially, static provisioning for a given distribution of heat loads and cooling resources is achieved to produce a reference state. A perturbation in reference state is introduced to simulate a very plausible scenario-failure of a computer room air conditioning (CRAC) unit. The transient model shows the "redlining" of inlet temperature of systems in the area that is most influenced by the failed CRAC. In this example high-density data center, the time to reach unacceptable inlet temperature is less than 80 seconds based on an example temperature set point limit of 40°C (most of today's servers would require an inlet temperature below 35°C to operate). An effective approach to resolve this issue, if there is adequate capacity, is to migrate the compute workload to other available systems within the data center to reduce the inlet temperature to the servers to an acceptable level.

KW - CFD analysis of data center

KW - Computer room cooling

KW - Cooling

KW - Cooling of data center

KW - Data center

KW - Exergy

KW - Heat

KW - Load migration

KW - Provisioning of data centers

KW - Smart cooling

KW - Transient analysis of data center

UR - http://www.scopus.com/inward/record.url?scp=34247560899&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=34247560899&partnerID=8YFLogxK

U2 - 10.1007/s10619-005-0413-0

DO - 10.1007/s10619-005-0413-0

M3 - Article

VL - 21

SP - 227

EP - 238

JO - Distributed and Parallel Databases

JF - Distributed and Parallel Databases

SN - 0926-8782

IS - 2-3

ER -