Układ napędowy z silnikiem indukcyjnym, umożliwiający równoczesną detekcję uszkodzeń bez stosowania dodatkowych czujników

Translated title of the contribution: Speed sensorless ac drive with inverter lc filter and fault detection using load torque signal

Jarosław Guziński, Haitham Abu-Rub, Patryk Strankowski

Research output: Contribution to journalArticle

Abstract

The industrial development in recent years has seen a major increase in the use of induction motors, whereby the cost has to be as low as possible and the lifetime as long as possible. To follow up this desire, investigations in this area have become very intense. For that reason, this paper presents a solution for driving an induction motor and simultaneous fault detection with no need for additional sensors. In order to achieve this target, an observer system is implemented and a torque estimation procedure is used for torque detection. An LC filter was installed at the inverter output to provide better THD of the current. The validation of the drive operation was achieved through simulation and experiments. To investigate possible faults, an artificial unbalance was introduced to the test bench, whereby the experiment was validated by a comparison of physical vibrations and estimated torque.

Original languagePolish
Pages (from-to)289-297
Number of pages9
JournalPrzeglad Elektrotechniczny
Volume93
Issue number2
DOIs
Publication statusPublished - 2017

Fingerprint

Fault detection
Loads (forces)
Torque
Induction motors
Experiments
Sensors
Costs

Keywords

  • Fault detection
  • Induction motor LC filter
  • Load torque observer
  • Sensorless drives
  • Voltage converter

ASJC Scopus subject areas

  • Electrical and Electronic Engineering

Cite this

Układ napędowy z silnikiem indukcyjnym, umożliwiający równoczesną detekcję uszkodzeń bez stosowania dodatkowych czujników. / Guziński, Jarosław; Abu-Rub, Haitham; Strankowski, Patryk.

In: Przeglad Elektrotechniczny, Vol. 93, No. 2, 2017, p. 289-297.

Research output: Contribution to journalArticle

@article{fa87aa35786b428491090b703c7bc9ac,
title = "Układ napędowy z silnikiem indukcyjnym, umożliwiający r{\'o}wnoczesną detekcję uszkodzeń bez stosowania dodatkowych czujnik{\'o}w",
abstract = "The industrial development in recent years has seen a major increase in the use of induction motors, whereby the cost has to be as low as possible and the lifetime as long as possible. To follow up this desire, investigations in this area have become very intense. For that reason, this paper presents a solution for driving an induction motor and simultaneous fault detection with no need for additional sensors. In order to achieve this target, an observer system is implemented and a torque estimation procedure is used for torque detection. An LC filter was installed at the inverter output to provide better THD of the current. The validation of the drive operation was achieved through simulation and experiments. To investigate possible faults, an artificial unbalance was introduced to the test bench, whereby the experiment was validated by a comparison of physical vibrations and estimated torque.",
keywords = "Fault detection, Induction motor LC filter, Load torque observer, Sensorless drives, Voltage converter",
author = "Jarosław Guziński and Haitham Abu-Rub and Patryk Strankowski",
year = "2017",
doi = "10.15199/48.2017.02.63",
language = "Polish",
volume = "93",
pages = "289--297",
journal = "Przeglad Elektrotechniczny",
issn = "0033-2097",
publisher = "Wydawnictwo SIGMA - N O T Sp. z o.o.",
number = "2",

}

TY - JOUR

T1 - Układ napędowy z silnikiem indukcyjnym, umożliwiający równoczesną detekcję uszkodzeń bez stosowania dodatkowych czujników

AU - Guziński, Jarosław

AU - Abu-Rub, Haitham

AU - Strankowski, Patryk

PY - 2017

Y1 - 2017

N2 - The industrial development in recent years has seen a major increase in the use of induction motors, whereby the cost has to be as low as possible and the lifetime as long as possible. To follow up this desire, investigations in this area have become very intense. For that reason, this paper presents a solution for driving an induction motor and simultaneous fault detection with no need for additional sensors. In order to achieve this target, an observer system is implemented and a torque estimation procedure is used for torque detection. An LC filter was installed at the inverter output to provide better THD of the current. The validation of the drive operation was achieved through simulation and experiments. To investigate possible faults, an artificial unbalance was introduced to the test bench, whereby the experiment was validated by a comparison of physical vibrations and estimated torque.

AB - The industrial development in recent years has seen a major increase in the use of induction motors, whereby the cost has to be as low as possible and the lifetime as long as possible. To follow up this desire, investigations in this area have become very intense. For that reason, this paper presents a solution for driving an induction motor and simultaneous fault detection with no need for additional sensors. In order to achieve this target, an observer system is implemented and a torque estimation procedure is used for torque detection. An LC filter was installed at the inverter output to provide better THD of the current. The validation of the drive operation was achieved through simulation and experiments. To investigate possible faults, an artificial unbalance was introduced to the test bench, whereby the experiment was validated by a comparison of physical vibrations and estimated torque.

KW - Fault detection

KW - Induction motor LC filter

KW - Load torque observer

KW - Sensorless drives

KW - Voltage converter

UR - http://www.scopus.com/inward/record.url?scp=85012249122&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85012249122&partnerID=8YFLogxK

U2 - 10.15199/48.2017.02.63

DO - 10.15199/48.2017.02.63

M3 - Article

AN - SCOPUS:85012249122

VL - 93

SP - 289

EP - 297

JO - Przeglad Elektrotechniczny

JF - Przeglad Elektrotechniczny

SN - 0033-2097

IS - 2