Smart cooling of data centers

Chandrakant D. Patel, Cullen E. Bash, Ratnesh Sharma, Monem Beitelmal, Rich Friedrich

Research output: Chapter in Book/Report/Conference proceedingConference contribution

121 Citations (Scopus)

Abstract

The data center of tomorrow is characterized as one containing a dense aggregation of commodity computing, networking and storage hardware mounted in industry standard racks. In fact, the data center is a computer. The walls of the data center are akin to the walls of the chassis in today's computer system. The new slim rack mounted systems and blade servers enable reduction in the footprint of today's data center by 66%. While maximizing computing per unit area, this compaction leads to extremely high power density and high cost associated with removal of the dissipated heat. Today's approach of cooling the entire data center to a constant temperature sampled at a single location, irrespective of the distributed utilization, is too energy inefficient. We propose a smart cooling system that provides localized cooling when and where needed and works in conjunction with a compute workload allocator to distribute compute workloads in the most energy efficient state. This paper shows a vision and construction of this intelligent data center that uses a combination of modeling, metrology and control to provision the air conditioning resources and workload distribution. A variable cooling system comprising variable capacity computer room air conditioning units, variable air moving devices, adjustable vents, etc. are used to dynamically allocate air conditioning resources where and when needed. A distributed metrology layer is used to sense environment variables like temperature and pressure, and power. The data center energy manager redistributes the compute workloads based on the most energy efficient availability of cooling resources and vice versa. The distributed control layer is no longer associated with any single localized temperature measurement but based on parameters calculated from an aggregation of sensors. The compute resources not in use are put on "standby" thereby providing added savings.

Original languageEnglish
Title of host publicationAdvances in Electronic Packaging 2003
Subtitle of host publicationVolume 2
Pages129-137
Number of pages9
Publication statusPublished - 1 Dec 2003
Event2003 International Electronic Packaging Technical Conference and Exhibition - Maui, HI, United States
Duration: 6 Jul 200311 Jul 2003

Publication series

NameAdvances in Electronic Packaging
Volume2

Other

Other2003 International Electronic Packaging Technical Conference and Exhibition
CountryUnited States
CityMaui, HI
Period6/7/0311/7/03

    Fingerprint

Keywords

  • Computer room air conditioning
  • Cooling
  • Data center
  • High power data center
  • Power
  • Smart cooling

ASJC Scopus subject areas

  • Engineering(all)
  • Electrical and Electronic Engineering
  • Electronic, Optical and Magnetic Materials