Removal of NH4 + Ion from NH4Cl Solution Using Clinoptilolite

A Dynamic Study Using a Continuous Packed-Bed Column in Up-Flow Mode

N. P. Hankins, S. Pliankarom, N. Hilal

Research output: Contribution to journalArticle

16 Citations (Scopus)

Abstract

An investigation, in the form of dynamic experiments, was designed to investigate equilibrium and kinetic information for the ammonium ion-exchange of clinoptilolite. The process consisted of a packed-bed column operated in up-flow mode. A number of experiments were carried out at laboratory scale. The total ionic strength was kept constant in all runs, and made to resemble the ionic environment of the effluent from the landfill assisted froth flotation (LLAFF) process, in order to validate the feasibility of using clinoptilolite to remove NH4 + ion from that wastewater. Breakthrough curves and reduced data of the Thomas equation were constructed from a range of experimental tests in order to determine maximum exchange capacity (q) and design reaction constant (k). Feed rate and packing techniques have a major effect on the dynamic condition inside the column. The influence of multi-component ions on the NH+ 4 ion-exchange performance of clinoptilolite was also studied in order to determine the negative effect of competing cations, i.e., K+, Ca2+, and Na+. The results of the study show that the column system gives an acceptable response to variable influent NH4 + loads. Desorption phenomena were also investigated when the influent was shifted to very low concentrations of NH+ 4 loads. Overall, a fixed-bed system of clinoptilolite shows high potential to remove Ma ion from the effluent of the LLAFF process.

Original languageEnglish
Pages (from-to)1347-1364
Number of pages18
JournalSeparation Science and Technology
Volume39
Issue number6
DOIs
Publication statusPublished - 2004
Externally publishedYes

Fingerprint

Packed beds
Froth flotation
Ions
Land fill
Effluents
Ion exchange
Ionic strength
Rate constants
Desorption
Wastewater
Positive ions
Experiments
Ammonium Compounds
Cations
Kinetics
clinoptilolite

Keywords

  • Ammonium removal
  • Clinoptilolite
  • Constant ionic strength
  • Dynamic study
  • Ion-exchange
  • Up-flow

ASJC Scopus subject areas

  • Chemistry(all)
  • Process Chemistry and Technology
  • Chemical Engineering(all)
  • Filtration and Separation

Cite this

Removal of NH4 + Ion from NH4Cl Solution Using Clinoptilolite : A Dynamic Study Using a Continuous Packed-Bed Column in Up-Flow Mode. / Hankins, N. P.; Pliankarom, S.; Hilal, N.

In: Separation Science and Technology, Vol. 39, No. 6, 2004, p. 1347-1364.

Research output: Contribution to journalArticle

@article{883f3856b99e430ba8068d00f98acc58,
title = "Removal of NH4 + Ion from NH4Cl Solution Using Clinoptilolite: A Dynamic Study Using a Continuous Packed-Bed Column in Up-Flow Mode",
abstract = "An investigation, in the form of dynamic experiments, was designed to investigate equilibrium and kinetic information for the ammonium ion-exchange of clinoptilolite. The process consisted of a packed-bed column operated in up-flow mode. A number of experiments were carried out at laboratory scale. The total ionic strength was kept constant in all runs, and made to resemble the ionic environment of the effluent from the landfill assisted froth flotation (LLAFF) process, in order to validate the feasibility of using clinoptilolite to remove NH4 + ion from that wastewater. Breakthrough curves and reduced data of the Thomas equation were constructed from a range of experimental tests in order to determine maximum exchange capacity (q) and design reaction constant (k). Feed rate and packing techniques have a major effect on the dynamic condition inside the column. The influence of multi-component ions on the NH+ 4 ion-exchange performance of clinoptilolite was also studied in order to determine the negative effect of competing cations, i.e., K+, Ca2+, and Na+. The results of the study show that the column system gives an acceptable response to variable influent NH4 + loads. Desorption phenomena were also investigated when the influent was shifted to very low concentrations of NH+ 4 loads. Overall, a fixed-bed system of clinoptilolite shows high potential to remove Ma ion from the effluent of the LLAFF process.",
keywords = "Ammonium removal, Clinoptilolite, Constant ionic strength, Dynamic study, Ion-exchange, Up-flow",
author = "Hankins, {N. P.} and S. Pliankarom and N. Hilal",
year = "2004",
doi = "10.1081/SS-120030487",
language = "English",
volume = "39",
pages = "1347--1364",
journal = "Separation Science and Technology (Philadelphia)",
issn = "0149-6395",
publisher = "Taylor and Francis Ltd.",
number = "6",

}

TY - JOUR

T1 - Removal of NH4 + Ion from NH4Cl Solution Using Clinoptilolite

T2 - A Dynamic Study Using a Continuous Packed-Bed Column in Up-Flow Mode

AU - Hankins, N. P.

AU - Pliankarom, S.

AU - Hilal, N.

PY - 2004

Y1 - 2004

N2 - An investigation, in the form of dynamic experiments, was designed to investigate equilibrium and kinetic information for the ammonium ion-exchange of clinoptilolite. The process consisted of a packed-bed column operated in up-flow mode. A number of experiments were carried out at laboratory scale. The total ionic strength was kept constant in all runs, and made to resemble the ionic environment of the effluent from the landfill assisted froth flotation (LLAFF) process, in order to validate the feasibility of using clinoptilolite to remove NH4 + ion from that wastewater. Breakthrough curves and reduced data of the Thomas equation were constructed from a range of experimental tests in order to determine maximum exchange capacity (q) and design reaction constant (k). Feed rate and packing techniques have a major effect on the dynamic condition inside the column. The influence of multi-component ions on the NH+ 4 ion-exchange performance of clinoptilolite was also studied in order to determine the negative effect of competing cations, i.e., K+, Ca2+, and Na+. The results of the study show that the column system gives an acceptable response to variable influent NH4 + loads. Desorption phenomena were also investigated when the influent was shifted to very low concentrations of NH+ 4 loads. Overall, a fixed-bed system of clinoptilolite shows high potential to remove Ma ion from the effluent of the LLAFF process.

AB - An investigation, in the form of dynamic experiments, was designed to investigate equilibrium and kinetic information for the ammonium ion-exchange of clinoptilolite. The process consisted of a packed-bed column operated in up-flow mode. A number of experiments were carried out at laboratory scale. The total ionic strength was kept constant in all runs, and made to resemble the ionic environment of the effluent from the landfill assisted froth flotation (LLAFF) process, in order to validate the feasibility of using clinoptilolite to remove NH4 + ion from that wastewater. Breakthrough curves and reduced data of the Thomas equation were constructed from a range of experimental tests in order to determine maximum exchange capacity (q) and design reaction constant (k). Feed rate and packing techniques have a major effect on the dynamic condition inside the column. The influence of multi-component ions on the NH+ 4 ion-exchange performance of clinoptilolite was also studied in order to determine the negative effect of competing cations, i.e., K+, Ca2+, and Na+. The results of the study show that the column system gives an acceptable response to variable influent NH4 + loads. Desorption phenomena were also investigated when the influent was shifted to very low concentrations of NH+ 4 loads. Overall, a fixed-bed system of clinoptilolite shows high potential to remove Ma ion from the effluent of the LLAFF process.

KW - Ammonium removal

KW - Clinoptilolite

KW - Constant ionic strength

KW - Dynamic study

KW - Ion-exchange

KW - Up-flow

UR - http://www.scopus.com/inward/record.url?scp=2142810116&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=2142810116&partnerID=8YFLogxK

U2 - 10.1081/SS-120030487

DO - 10.1081/SS-120030487

M3 - Article

VL - 39

SP - 1347

EP - 1364

JO - Separation Science and Technology (Philadelphia)

JF - Separation Science and Technology (Philadelphia)

SN - 0149-6395

IS - 6

ER -