Prediction of Microdroplet Breakup Regime in Asymmetric T-Junction Microchannels

Way Lee Cheng, Reza Sadr, Jing Dai, Arum Han

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

Splitting droplets is becoming a major functional component in increasing number of droplet microfluidic applications, and there is an increasing interest in splitting droplets into two daughter droplets with different volumes. However, designing an asymmetric droplet splitter and predicting how a droplet splits in such designs is not trivial. In this study, numerical simulations were conducted to study droplet breakup in asymmetric T-junctions of square cross-sections having different pressure gradient ratios (i.e. T-junctions with outlet branches of different lengths). The goal of the simulation is to identify the conditions where a parent droplet breaks or does not break into two smaller droplets of different sizes (so called critical condition) and to identify the important fluid and microchannel parameters in this process. Four modes of droplet breakup (primary-, transition-, bubble-, and non-breakups) are identified and an empirical correlation is introduced that can predict the breakup/non-breakup of the droplet based on the parent droplet size and the capillary number. The simulation results are then compared with experimental data to verify its accuracy and the effect of fluids properties on the proposed correlation are studied. Two major asymmetric breakup mechanisms are determined, namely “breakup with permanent obstruction” and “unstable breakup”. The numerical results show that the splitting ratio for the asymmetric breakup mechanisms depends on flow conditions and dwell time of the droplet at the junction prior to splitting. Finally, the results from two-dimensional and three-dimensional simulations were compared. It is shown that two-dimensional simulation may not accurately predict the breakup behavior for asymmetric droplet breakup and viscosity ration has a greater effect on the prediction critical condition.

Original languageEnglish
Article number72
JournalBiomedical Microdevices
Volume20
Issue number3
DOIs
Publication statusPublished - 1 Sep 2018

Fingerprint

Microfluidics
Microchannels
Viscosity
Pressure
Fluids
Pressure gradient
Bubbles (in fluids)

Keywords

  • Asymmetric T-junction
  • Breakup
  • Computational fluid dynamics (CFD)
  • Criteria
  • Droplet split

ASJC Scopus subject areas

  • Biomedical Engineering
  • Molecular Biology

Cite this

Prediction of Microdroplet Breakup Regime in Asymmetric T-Junction Microchannels. / Cheng, Way Lee; Sadr, Reza; Dai, Jing; Han, Arum.

In: Biomedical Microdevices, Vol. 20, No. 3, 72, 01.09.2018.

Research output: Contribution to journalArticle

@article{656978fd0e314a06857b93a1aeaaad67,
title = "Prediction of Microdroplet Breakup Regime in Asymmetric T-Junction Microchannels",
abstract = "Splitting droplets is becoming a major functional component in increasing number of droplet microfluidic applications, and there is an increasing interest in splitting droplets into two daughter droplets with different volumes. However, designing an asymmetric droplet splitter and predicting how a droplet splits in such designs is not trivial. In this study, numerical simulations were conducted to study droplet breakup in asymmetric T-junctions of square cross-sections having different pressure gradient ratios (i.e. T-junctions with outlet branches of different lengths). The goal of the simulation is to identify the conditions where a parent droplet breaks or does not break into two smaller droplets of different sizes (so called critical condition) and to identify the important fluid and microchannel parameters in this process. Four modes of droplet breakup (primary-, transition-, bubble-, and non-breakups) are identified and an empirical correlation is introduced that can predict the breakup/non-breakup of the droplet based on the parent droplet size and the capillary number. The simulation results are then compared with experimental data to verify its accuracy and the effect of fluids properties on the proposed correlation are studied. Two major asymmetric breakup mechanisms are determined, namely “breakup with permanent obstruction” and “unstable breakup”. The numerical results show that the splitting ratio for the asymmetric breakup mechanisms depends on flow conditions and dwell time of the droplet at the junction prior to splitting. Finally, the results from two-dimensional and three-dimensional simulations were compared. It is shown that two-dimensional simulation may not accurately predict the breakup behavior for asymmetric droplet breakup and viscosity ration has a greater effect on the prediction critical condition.",
keywords = "Asymmetric T-junction, Breakup, Computational fluid dynamics (CFD), Criteria, Droplet split",
author = "Cheng, {Way Lee} and Reza Sadr and Jing Dai and Arum Han",
year = "2018",
month = "9",
day = "1",
doi = "10.1007/s10544-018-0310-8",
language = "English",
volume = "20",
journal = "Biomedical Microdevices",
issn = "1387-2176",
publisher = "Kluwer Academic Publishers",
number = "3",

}

TY - JOUR

T1 - Prediction of Microdroplet Breakup Regime in Asymmetric T-Junction Microchannels

AU - Cheng, Way Lee

AU - Sadr, Reza

AU - Dai, Jing

AU - Han, Arum

PY - 2018/9/1

Y1 - 2018/9/1

N2 - Splitting droplets is becoming a major functional component in increasing number of droplet microfluidic applications, and there is an increasing interest in splitting droplets into two daughter droplets with different volumes. However, designing an asymmetric droplet splitter and predicting how a droplet splits in such designs is not trivial. In this study, numerical simulations were conducted to study droplet breakup in asymmetric T-junctions of square cross-sections having different pressure gradient ratios (i.e. T-junctions with outlet branches of different lengths). The goal of the simulation is to identify the conditions where a parent droplet breaks or does not break into two smaller droplets of different sizes (so called critical condition) and to identify the important fluid and microchannel parameters in this process. Four modes of droplet breakup (primary-, transition-, bubble-, and non-breakups) are identified and an empirical correlation is introduced that can predict the breakup/non-breakup of the droplet based on the parent droplet size and the capillary number. The simulation results are then compared with experimental data to verify its accuracy and the effect of fluids properties on the proposed correlation are studied. Two major asymmetric breakup mechanisms are determined, namely “breakup with permanent obstruction” and “unstable breakup”. The numerical results show that the splitting ratio for the asymmetric breakup mechanisms depends on flow conditions and dwell time of the droplet at the junction prior to splitting. Finally, the results from two-dimensional and three-dimensional simulations were compared. It is shown that two-dimensional simulation may not accurately predict the breakup behavior for asymmetric droplet breakup and viscosity ration has a greater effect on the prediction critical condition.

AB - Splitting droplets is becoming a major functional component in increasing number of droplet microfluidic applications, and there is an increasing interest in splitting droplets into two daughter droplets with different volumes. However, designing an asymmetric droplet splitter and predicting how a droplet splits in such designs is not trivial. In this study, numerical simulations were conducted to study droplet breakup in asymmetric T-junctions of square cross-sections having different pressure gradient ratios (i.e. T-junctions with outlet branches of different lengths). The goal of the simulation is to identify the conditions where a parent droplet breaks or does not break into two smaller droplets of different sizes (so called critical condition) and to identify the important fluid and microchannel parameters in this process. Four modes of droplet breakup (primary-, transition-, bubble-, and non-breakups) are identified and an empirical correlation is introduced that can predict the breakup/non-breakup of the droplet based on the parent droplet size and the capillary number. The simulation results are then compared with experimental data to verify its accuracy and the effect of fluids properties on the proposed correlation are studied. Two major asymmetric breakup mechanisms are determined, namely “breakup with permanent obstruction” and “unstable breakup”. The numerical results show that the splitting ratio for the asymmetric breakup mechanisms depends on flow conditions and dwell time of the droplet at the junction prior to splitting. Finally, the results from two-dimensional and three-dimensional simulations were compared. It is shown that two-dimensional simulation may not accurately predict the breakup behavior for asymmetric droplet breakup and viscosity ration has a greater effect on the prediction critical condition.

KW - Asymmetric T-junction

KW - Breakup

KW - Computational fluid dynamics (CFD)

KW - Criteria

KW - Droplet split

UR - http://www.scopus.com/inward/record.url?scp=85051484152&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85051484152&partnerID=8YFLogxK

U2 - 10.1007/s10544-018-0310-8

DO - 10.1007/s10544-018-0310-8

M3 - Article

VL - 20

JO - Biomedical Microdevices

JF - Biomedical Microdevices

SN - 1387-2176

IS - 3

M1 - 72

ER -