Monitoring of wastewater treatment plants using improved univariate statistical technique

Imen Baklouti, Majdi Mansouri, Ahmed Ben Hamida, Hazem Nounou, Mohamed Nounou

Research output: Contribution to journalArticle

16 Citations (Scopus)

Abstract

Proper operation of the wastewater treatment plants (WWTPs) is crucial in order to maintain the sought effectiveness and desirable water quality. Therefore, the objective of this paper is to develop univariate statistical technique that aims at enhancing the monitoring of wastewater treatment plants using an improved particle filtering (IPF)-based multiscale optimized exponentially weighted moving average chart (MS-OEWMA). The advantages of the developed technique are fivefold: (i) estimate a nonlinear state variables of WWTPs using IPF technique. The IPF method yields an optimum choice of the sampling distribution, which also accounts for the observed data; (ii) use the dynamical multiscale representation to extract accurate deterministic features and decorrelate autocorrelated measurements. (iii) Develop an optimized EWMA (OEWMA) based on the best selection of smoothing parameter (λ) and control width L; (iv) combine the advantages of state estimation technique with MS-OEWMA chart to improve the fault detection in WWTP systems; and (v) investigate the effect of fault types (offset or bias, variance and drift) and fault sizes on the fault detection performances. The developed technique is validated using simulated COST wastewater treatment BSM1 model. The BSM1, provided by the IWA Task Group on Benchmarking of Control Strategies, is a simulation platform that allows for creating sensor faults disturbances in a wastewater treatment plant. The detection results are evaluated using three fault detection criteria: missed detection rate (MDR), false alarm rate (FAR) and average run length (ARL1).

Original languageEnglish
Pages (from-to)287-300
Number of pages14
JournalProcess Safety and Environmental Protection
Volume116
DOIs
Publication statusPublished - 1 May 2018

Fingerprint

Wastewater treatment
Monitoring
monitoring
Fault detection
benchmarking
Benchmarking
State estimation
smoothing
Water quality
wastewater treatment plant
detection
Sampling
sensor
water quality
disturbance
Sensors
sampling
simulation
particle
rate

Keywords

  • Exponentially weighted moving average (EWMA)
  • Fault detection (FD)
  • Improved particle filter (IPF)
  • Wastewater treatment plant (WWTP)
  • Wavelet representation

ASJC Scopus subject areas

  • Environmental Engineering
  • Environmental Chemistry
  • Chemical Engineering(all)
  • Safety, Risk, Reliability and Quality

Cite this

Monitoring of wastewater treatment plants using improved univariate statistical technique. / Baklouti, Imen; Mansouri, Majdi; Hamida, Ahmed Ben; Nounou, Hazem; Nounou, Mohamed.

In: Process Safety and Environmental Protection, Vol. 116, 01.05.2018, p. 287-300.

Research output: Contribution to journalArticle

@article{ae3f0ff4c7404c3ebc7796633f98be22,
title = "Monitoring of wastewater treatment plants using improved univariate statistical technique",
abstract = "Proper operation of the wastewater treatment plants (WWTPs) is crucial in order to maintain the sought effectiveness and desirable water quality. Therefore, the objective of this paper is to develop univariate statistical technique that aims at enhancing the monitoring of wastewater treatment plants using an improved particle filtering (IPF)-based multiscale optimized exponentially weighted moving average chart (MS-OEWMA). The advantages of the developed technique are fivefold: (i) estimate a nonlinear state variables of WWTPs using IPF technique. The IPF method yields an optimum choice of the sampling distribution, which also accounts for the observed data; (ii) use the dynamical multiscale representation to extract accurate deterministic features and decorrelate autocorrelated measurements. (iii) Develop an optimized EWMA (OEWMA) based on the best selection of smoothing parameter (λ) and control width L; (iv) combine the advantages of state estimation technique with MS-OEWMA chart to improve the fault detection in WWTP systems; and (v) investigate the effect of fault types (offset or bias, variance and drift) and fault sizes on the fault detection performances. The developed technique is validated using simulated COST wastewater treatment BSM1 model. The BSM1, provided by the IWA Task Group on Benchmarking of Control Strategies, is a simulation platform that allows for creating sensor faults disturbances in a wastewater treatment plant. The detection results are evaluated using three fault detection criteria: missed detection rate (MDR), false alarm rate (FAR) and average run length (ARL1).",
keywords = "Exponentially weighted moving average (EWMA), Fault detection (FD), Improved particle filter (IPF), Wastewater treatment plant (WWTP), Wavelet representation",
author = "Imen Baklouti and Majdi Mansouri and Hamida, {Ahmed Ben} and Hazem Nounou and Mohamed Nounou",
year = "2018",
month = "5",
day = "1",
doi = "10.1016/j.psep.2018.02.006",
language = "English",
volume = "116",
pages = "287--300",
journal = "Process Safety and Environmental Protection",
issn = "0957-5820",
publisher = "Institution of Chemical Engineers",

}

TY - JOUR

T1 - Monitoring of wastewater treatment plants using improved univariate statistical technique

AU - Baklouti, Imen

AU - Mansouri, Majdi

AU - Hamida, Ahmed Ben

AU - Nounou, Hazem

AU - Nounou, Mohamed

PY - 2018/5/1

Y1 - 2018/5/1

N2 - Proper operation of the wastewater treatment plants (WWTPs) is crucial in order to maintain the sought effectiveness and desirable water quality. Therefore, the objective of this paper is to develop univariate statistical technique that aims at enhancing the monitoring of wastewater treatment plants using an improved particle filtering (IPF)-based multiscale optimized exponentially weighted moving average chart (MS-OEWMA). The advantages of the developed technique are fivefold: (i) estimate a nonlinear state variables of WWTPs using IPF technique. The IPF method yields an optimum choice of the sampling distribution, which also accounts for the observed data; (ii) use the dynamical multiscale representation to extract accurate deterministic features and decorrelate autocorrelated measurements. (iii) Develop an optimized EWMA (OEWMA) based on the best selection of smoothing parameter (λ) and control width L; (iv) combine the advantages of state estimation technique with MS-OEWMA chart to improve the fault detection in WWTP systems; and (v) investigate the effect of fault types (offset or bias, variance and drift) and fault sizes on the fault detection performances. The developed technique is validated using simulated COST wastewater treatment BSM1 model. The BSM1, provided by the IWA Task Group on Benchmarking of Control Strategies, is a simulation platform that allows for creating sensor faults disturbances in a wastewater treatment plant. The detection results are evaluated using three fault detection criteria: missed detection rate (MDR), false alarm rate (FAR) and average run length (ARL1).

AB - Proper operation of the wastewater treatment plants (WWTPs) is crucial in order to maintain the sought effectiveness and desirable water quality. Therefore, the objective of this paper is to develop univariate statistical technique that aims at enhancing the monitoring of wastewater treatment plants using an improved particle filtering (IPF)-based multiscale optimized exponentially weighted moving average chart (MS-OEWMA). The advantages of the developed technique are fivefold: (i) estimate a nonlinear state variables of WWTPs using IPF technique. The IPF method yields an optimum choice of the sampling distribution, which also accounts for the observed data; (ii) use the dynamical multiscale representation to extract accurate deterministic features and decorrelate autocorrelated measurements. (iii) Develop an optimized EWMA (OEWMA) based on the best selection of smoothing parameter (λ) and control width L; (iv) combine the advantages of state estimation technique with MS-OEWMA chart to improve the fault detection in WWTP systems; and (v) investigate the effect of fault types (offset or bias, variance and drift) and fault sizes on the fault detection performances. The developed technique is validated using simulated COST wastewater treatment BSM1 model. The BSM1, provided by the IWA Task Group on Benchmarking of Control Strategies, is a simulation platform that allows for creating sensor faults disturbances in a wastewater treatment plant. The detection results are evaluated using three fault detection criteria: missed detection rate (MDR), false alarm rate (FAR) and average run length (ARL1).

KW - Exponentially weighted moving average (EWMA)

KW - Fault detection (FD)

KW - Improved particle filter (IPF)

KW - Wastewater treatment plant (WWTP)

KW - Wavelet representation

UR - http://www.scopus.com/inward/record.url?scp=85042677525&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85042677525&partnerID=8YFLogxK

U2 - 10.1016/j.psep.2018.02.006

DO - 10.1016/j.psep.2018.02.006

M3 - Article

VL - 116

SP - 287

EP - 300

JO - Process Safety and Environmental Protection

JF - Process Safety and Environmental Protection

SN - 0957-5820