We developed a mid-infrared dual frequency comb spectrometer with a multipass cell of ~580 m effective length for acetone detection. The detection limit is ~ 2 ppmv under ambient air condition with 80 ms acquisition time.

Original languageEnglish
Title of host publicationLaser Applications to Chemical, Security and Environmental Analysis, LACSEA 2016
PublisherOSA - The Optical Society
ISBN (Print)9781943580156
DOIs
Publication statusPublished - 18 Jul 2016
EventLaser Applications to Chemical, Security and Environmental Analysis, LACSEA 2016 - Heidelberg, Germany
Duration: 25 Jul 201628 Jul 2016

Other

OtherLaser Applications to Chemical, Security and Environmental Analysis, LACSEA 2016
CountryGermany
CityHeidelberg
Period25/7/1628/7/16

Fingerprint

Acetone
Spectrometers
Infrared radiation
Air

ASJC Scopus subject areas

  • Electronic, Optical and Magnetic Materials
  • Mechanics of Materials

Cite this

Zhu, F., Bicer, A., Bounds, J., Xia, J., Kolomenskii, A. A., Mohamed, T. A., ... Schuessler, H. A. (2016). Mid-infrared dual frequency comb spectrometer for acetone detection. In Laser Applications to Chemical, Security and Environmental Analysis, LACSEA 2016 OSA - The Optical Society. https://doi.org/10.1364/LACSEA.2016.LT1G.2

Mid-infrared dual frequency comb spectrometer for acetone detection. / Zhu, Feng; Bicer, Aysenur; Bounds, James; Xia, Jinbao; Kolomenskii, Alexandre A.; Mohamed, Tarek A.; Amani, Mahmood; Schuessler, Hans A.

Laser Applications to Chemical, Security and Environmental Analysis, LACSEA 2016. OSA - The Optical Society, 2016.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Zhu, F, Bicer, A, Bounds, J, Xia, J, Kolomenskii, AA, Mohamed, TA, Amani, M & Schuessler, HA 2016, Mid-infrared dual frequency comb spectrometer for acetone detection. in Laser Applications to Chemical, Security and Environmental Analysis, LACSEA 2016. OSA - The Optical Society, Laser Applications to Chemical, Security and Environmental Analysis, LACSEA 2016, Heidelberg, Germany, 25/7/16. https://doi.org/10.1364/LACSEA.2016.LT1G.2
Zhu F, Bicer A, Bounds J, Xia J, Kolomenskii AA, Mohamed TA et al. Mid-infrared dual frequency comb spectrometer for acetone detection. In Laser Applications to Chemical, Security and Environmental Analysis, LACSEA 2016. OSA - The Optical Society. 2016 https://doi.org/10.1364/LACSEA.2016.LT1G.2
Zhu, Feng ; Bicer, Aysenur ; Bounds, James ; Xia, Jinbao ; Kolomenskii, Alexandre A. ; Mohamed, Tarek A. ; Amani, Mahmood ; Schuessler, Hans A. / Mid-infrared dual frequency comb spectrometer for acetone detection. Laser Applications to Chemical, Security and Environmental Analysis, LACSEA 2016. OSA - The Optical Society, 2016.
@inproceedings{ae74e005f93840b8bfa9840bafcd1cf6,
title = "Mid-infrared dual frequency comb spectrometer for acetone detection",
abstract = "We developed a mid-infrared dual frequency comb spectrometer with a multipass cell of ~580 m effective length for acetone detection. The detection limit is ~ 2 ppmv under ambient air condition with 80 ms acquisition time.",
author = "Feng Zhu and Aysenur Bicer and James Bounds and Jinbao Xia and Kolomenskii, {Alexandre A.} and Mohamed, {Tarek A.} and Mahmood Amani and Schuessler, {Hans A.}",
year = "2016",
month = "7",
day = "18",
doi = "10.1364/LACSEA.2016.LT1G.2",
language = "English",
isbn = "9781943580156",
booktitle = "Laser Applications to Chemical, Security and Environmental Analysis, LACSEA 2016",
publisher = "OSA - The Optical Society",

}

TY - GEN

T1 - Mid-infrared dual frequency comb spectrometer for acetone detection

AU - Zhu, Feng

AU - Bicer, Aysenur

AU - Bounds, James

AU - Xia, Jinbao

AU - Kolomenskii, Alexandre A.

AU - Mohamed, Tarek A.

AU - Amani, Mahmood

AU - Schuessler, Hans A.

PY - 2016/7/18

Y1 - 2016/7/18

N2 - We developed a mid-infrared dual frequency comb spectrometer with a multipass cell of ~580 m effective length for acetone detection. The detection limit is ~ 2 ppmv under ambient air condition with 80 ms acquisition time.

AB - We developed a mid-infrared dual frequency comb spectrometer with a multipass cell of ~580 m effective length for acetone detection. The detection limit is ~ 2 ppmv under ambient air condition with 80 ms acquisition time.

UR - http://www.scopus.com/inward/record.url?scp=85019512806&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85019512806&partnerID=8YFLogxK

U2 - 10.1364/LACSEA.2016.LT1G.2

DO - 10.1364/LACSEA.2016.LT1G.2

M3 - Conference contribution

SN - 9781943580156

BT - Laser Applications to Chemical, Security and Environmental Analysis, LACSEA 2016

PB - OSA - The Optical Society

ER -