Micromachined bolometers on polyimide

Aamer Mahmoud, Donald P. Butler, Zeynep Çelik-Butler

Research output: Contribution to journalArticle

29 Citations (Scopus)

Abstract

This paper presents design, fabrication and measured performance parameters of micromachined infrared detectors on polyimide substrates. The detectors are of bolometer type made of semiconducting yttrium-barium-copper oxide (YBCO) as the thermometer material and are built on a 40-50 μm-thick layer of polyimide (PI5878G) that serves as a flexible substrate. A thin film of Si3N4 supports the detectors. Surface micromachining is used to isolate the detectors and the supporting nitride layer from the substrate. Despite being supported by a layer of Si3N4, an average thermal conductivity of 5.61 × 10-7 W/K, comparable to self-supporting devices on flexible substrates has been measured. This opens the possibility of placing such flexible sensors on micromachined membranes, integrated with other functions such as pressure sensing to build "Smart Skin." Room-temperature responsivity of 7.4 × 103 V/W and detectivity of 6.6 × 105 cm Hz1/2/W were demonstrated on 40 μm × 40 μm microbolometers. The effect of substrate heating was also investigated and was found not to cause cross talk between the pixels. If these sensors are to be used as part of multi-functional, flexible sensor systems, device-level vacuum packaging is necessary. This was investigated using computer simulations for structural analysis and found to be feasible.

Original languageEnglish
Pages (from-to)452-459
Number of pages8
JournalSensors and Actuators, A: Physical
Volume132
Issue number2
DOIs
Publication statusPublished - 20 Nov 2006
Externally publishedYes

Fingerprint

Bolometers
bolometers
polyimides
Polyimides
Substrates
Detectors
sensors
detectors
Sensors
Yttrium barium copper oxides
barium oxides
Surface micromachining
Infrared detectors
Thermometers
infrared detectors
thermometers
copper oxides
micromachining
yttrium
structural analysis

Keywords

  • Finite-element analysis
  • Flexible sensors
  • Microbolometers
  • Micromachining
  • Thermal sensors
  • Wafer-level packaging

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Mechanical Engineering
  • Instrumentation

Cite this

Micromachined bolometers on polyimide. / Mahmoud, Aamer; Butler, Donald P.; Çelik-Butler, Zeynep.

In: Sensors and Actuators, A: Physical, Vol. 132, No. 2, 20.11.2006, p. 452-459.

Research output: Contribution to journalArticle

Mahmoud, Aamer ; Butler, Donald P. ; Çelik-Butler, Zeynep. / Micromachined bolometers on polyimide. In: Sensors and Actuators, A: Physical. 2006 ; Vol. 132, No. 2. pp. 452-459.
@article{acccc8b8fef2412686a1ad017de8f628,
title = "Micromachined bolometers on polyimide",
abstract = "This paper presents design, fabrication and measured performance parameters of micromachined infrared detectors on polyimide substrates. The detectors are of bolometer type made of semiconducting yttrium-barium-copper oxide (YBCO) as the thermometer material and are built on a 40-50 μm-thick layer of polyimide (PI5878G) that serves as a flexible substrate. A thin film of Si3N4 supports the detectors. Surface micromachining is used to isolate the detectors and the supporting nitride layer from the substrate. Despite being supported by a layer of Si3N4, an average thermal conductivity of 5.61 × 10-7 W/K, comparable to self-supporting devices on flexible substrates has been measured. This opens the possibility of placing such flexible sensors on micromachined membranes, integrated with other functions such as pressure sensing to build {"}Smart Skin.{"} Room-temperature responsivity of 7.4 × 103 V/W and detectivity of 6.6 × 105 cm Hz1/2/W were demonstrated on 40 μm × 40 μm microbolometers. The effect of substrate heating was also investigated and was found not to cause cross talk between the pixels. If these sensors are to be used as part of multi-functional, flexible sensor systems, device-level vacuum packaging is necessary. This was investigated using computer simulations for structural analysis and found to be feasible.",
keywords = "Finite-element analysis, Flexible sensors, Microbolometers, Micromachining, Thermal sensors, Wafer-level packaging",
author = "Aamer Mahmoud and Butler, {Donald P.} and Zeynep {\cC}elik-Butler",
year = "2006",
month = "11",
day = "20",
doi = "10.1016/j.sna.2006.03.006",
language = "English",
volume = "132",
pages = "452--459",
journal = "Sensors and Actuators, A: Physical",
issn = "0924-4247",
publisher = "Elsevier",
number = "2",

}

TY - JOUR

T1 - Micromachined bolometers on polyimide

AU - Mahmoud, Aamer

AU - Butler, Donald P.

AU - Çelik-Butler, Zeynep

PY - 2006/11/20

Y1 - 2006/11/20

N2 - This paper presents design, fabrication and measured performance parameters of micromachined infrared detectors on polyimide substrates. The detectors are of bolometer type made of semiconducting yttrium-barium-copper oxide (YBCO) as the thermometer material and are built on a 40-50 μm-thick layer of polyimide (PI5878G) that serves as a flexible substrate. A thin film of Si3N4 supports the detectors. Surface micromachining is used to isolate the detectors and the supporting nitride layer from the substrate. Despite being supported by a layer of Si3N4, an average thermal conductivity of 5.61 × 10-7 W/K, comparable to self-supporting devices on flexible substrates has been measured. This opens the possibility of placing such flexible sensors on micromachined membranes, integrated with other functions such as pressure sensing to build "Smart Skin." Room-temperature responsivity of 7.4 × 103 V/W and detectivity of 6.6 × 105 cm Hz1/2/W were demonstrated on 40 μm × 40 μm microbolometers. The effect of substrate heating was also investigated and was found not to cause cross talk between the pixels. If these sensors are to be used as part of multi-functional, flexible sensor systems, device-level vacuum packaging is necessary. This was investigated using computer simulations for structural analysis and found to be feasible.

AB - This paper presents design, fabrication and measured performance parameters of micromachined infrared detectors on polyimide substrates. The detectors are of bolometer type made of semiconducting yttrium-barium-copper oxide (YBCO) as the thermometer material and are built on a 40-50 μm-thick layer of polyimide (PI5878G) that serves as a flexible substrate. A thin film of Si3N4 supports the detectors. Surface micromachining is used to isolate the detectors and the supporting nitride layer from the substrate. Despite being supported by a layer of Si3N4, an average thermal conductivity of 5.61 × 10-7 W/K, comparable to self-supporting devices on flexible substrates has been measured. This opens the possibility of placing such flexible sensors on micromachined membranes, integrated with other functions such as pressure sensing to build "Smart Skin." Room-temperature responsivity of 7.4 × 103 V/W and detectivity of 6.6 × 105 cm Hz1/2/W were demonstrated on 40 μm × 40 μm microbolometers. The effect of substrate heating was also investigated and was found not to cause cross talk between the pixels. If these sensors are to be used as part of multi-functional, flexible sensor systems, device-level vacuum packaging is necessary. This was investigated using computer simulations for structural analysis and found to be feasible.

KW - Finite-element analysis

KW - Flexible sensors

KW - Microbolometers

KW - Micromachining

KW - Thermal sensors

KW - Wafer-level packaging

UR - http://www.scopus.com/inward/record.url?scp=33750716905&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33750716905&partnerID=8YFLogxK

U2 - 10.1016/j.sna.2006.03.006

DO - 10.1016/j.sna.2006.03.006

M3 - Article

VL - 132

SP - 452

EP - 459

JO - Sensors and Actuators, A: Physical

JF - Sensors and Actuators, A: Physical

SN - 0924-4247

IS - 2

ER -