For microgrid interfaced sources, L-type filters are very useful for decoupling real and reactive power controls, but it has no voltage control loop. The absence of voltage loops complicates the implementations of virtual impedances and/or performing harmonics compensation. In this paper, methods are proposed to implement virtual impedances and compensate for the harmonics in L-type filters. The methods are verified by simulations and experimentally.

Original languageEnglish
Title of host publicationConference Proceedings - IEEE Applied Power Electronics Conference and Exposition - APEC
Pages2947-2952
Number of pages6
DOIs
Publication statusPublished - 2013
Externally publishedYes
Event28th Annual IEEE Applied Power Electronics Conference and Exposition, APEC 2013 - Long Beach, CA, United States
Duration: 17 Mar 201321 Mar 2013

Other

Other28th Annual IEEE Applied Power Electronics Conference and Exposition, APEC 2013
CountryUnited States
CityLong Beach, CA
Period17/3/1321/3/13

Fingerprint

Reactive power
Power control
Voltage control
Electric potential
Compensation and Redress

ASJC Scopus subject areas

  • Electrical and Electronic Engineering

Cite this

Elrayyah, A., & Sozer, Y. (2013). Improving the operation of microgrid interfaced inverter using L-type filter. In Conference Proceedings - IEEE Applied Power Electronics Conference and Exposition - APEC (pp. 2947-2952). [6520717] https://doi.org/10.1109/APEC.2013.6520717

Improving the operation of microgrid interfaced inverter using L-type filter. / Elrayyah, Ali; Sozer, Yilmaz.

Conference Proceedings - IEEE Applied Power Electronics Conference and Exposition - APEC. 2013. p. 2947-2952 6520717.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Elrayyah, A & Sozer, Y 2013, Improving the operation of microgrid interfaced inverter using L-type filter. in Conference Proceedings - IEEE Applied Power Electronics Conference and Exposition - APEC., 6520717, pp. 2947-2952, 28th Annual IEEE Applied Power Electronics Conference and Exposition, APEC 2013, Long Beach, CA, United States, 17/3/13. https://doi.org/10.1109/APEC.2013.6520717
Elrayyah A, Sozer Y. Improving the operation of microgrid interfaced inverter using L-type filter. In Conference Proceedings - IEEE Applied Power Electronics Conference and Exposition - APEC. 2013. p. 2947-2952. 6520717 https://doi.org/10.1109/APEC.2013.6520717
Elrayyah, Ali ; Sozer, Yilmaz. / Improving the operation of microgrid interfaced inverter using L-type filter. Conference Proceedings - IEEE Applied Power Electronics Conference and Exposition - APEC. 2013. pp. 2947-2952
@inproceedings{53e76c137e60468e99a1beaa91113fac,
title = "Improving the operation of microgrid interfaced inverter using L-type filter",
abstract = "For microgrid interfaced sources, L-type filters are very useful for decoupling real and reactive power controls, but it has no voltage control loop. The absence of voltage loops complicates the implementations of virtual impedances and/or performing harmonics compensation. In this paper, methods are proposed to implement virtual impedances and compensate for the harmonics in L-type filters. The methods are verified by simulations and experimentally.",
author = "Ali Elrayyah and Yilmaz Sozer",
year = "2013",
doi = "10.1109/APEC.2013.6520717",
language = "English",
isbn = "9781467343541",
pages = "2947--2952",
booktitle = "Conference Proceedings - IEEE Applied Power Electronics Conference and Exposition - APEC",

}

TY - GEN

T1 - Improving the operation of microgrid interfaced inverter using L-type filter

AU - Elrayyah, Ali

AU - Sozer, Yilmaz

PY - 2013

Y1 - 2013

N2 - For microgrid interfaced sources, L-type filters are very useful for decoupling real and reactive power controls, but it has no voltage control loop. The absence of voltage loops complicates the implementations of virtual impedances and/or performing harmonics compensation. In this paper, methods are proposed to implement virtual impedances and compensate for the harmonics in L-type filters. The methods are verified by simulations and experimentally.

AB - For microgrid interfaced sources, L-type filters are very useful for decoupling real and reactive power controls, but it has no voltage control loop. The absence of voltage loops complicates the implementations of virtual impedances and/or performing harmonics compensation. In this paper, methods are proposed to implement virtual impedances and compensate for the harmonics in L-type filters. The methods are verified by simulations and experimentally.

UR - http://www.scopus.com/inward/record.url?scp=84879326340&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84879326340&partnerID=8YFLogxK

U2 - 10.1109/APEC.2013.6520717

DO - 10.1109/APEC.2013.6520717

M3 - Conference contribution

AN - SCOPUS:84879326340

SN - 9781467343541

SP - 2947

EP - 2952

BT - Conference Proceedings - IEEE Applied Power Electronics Conference and Exposition - APEC

ER -