Experimental measurements and theoretical prediction for the transient characteristic of a two-phase two-component direct contact condenser

Hameed B. Mahood, Rex B. Thorpe, Alasdair N. Campbell, Adel O. Sharif

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

The transient characteristics of a three-phase direct contact condenser have been investigated experimentally, utilising a short Perspex column with 48 cm active height and 4 cm internal diameter, and theoretically. Two immiscible fluids, namely pentane vapour with varied initial temperature (41.5 °C, 43.5 °C and47.5 °C) and constant temperature (19 °C) tap water were exploited as the dispersed and the continuous phases respectively. A theoretical model to predict the continuous phase outlet temperature has been developed and solved numerically using MATLAB. The time dependent temperature distribution along the direct contact column was measured and the effect of the mass flow rate ratio and the initial dispersed phase temperature was studied. The experimental results showed that the continuous phase temperatures along the direct contact column increase with time. In addition, no significant effect of the dispersed phase initial temperature on the outlet temperature of the continuous phase was observed. This means that latent heat is dominant in such a direct contact process. Good agreement is achieved between the present theoretical model and the experimental data.

Original languageEnglish
Pages (from-to)161-174
Number of pages14
JournalApplied Thermal Engineering
Volume87
DOIs
Publication statusPublished - 30 May 2015

Fingerprint

Temperature
Latent heat
MATLAB
Temperature distribution
Vapors
Flow rate
Fluids
Water

Keywords

  • Direct contact condenser
  • Heat transfer
  • Transient temperature

ASJC Scopus subject areas

  • Energy Engineering and Power Technology
  • Industrial and Manufacturing Engineering

Cite this

Experimental measurements and theoretical prediction for the transient characteristic of a two-phase two-component direct contact condenser. / Mahood, Hameed B.; Thorpe, Rex B.; Campbell, Alasdair N.; Sharif, Adel O.

In: Applied Thermal Engineering, Vol. 87, 30.05.2015, p. 161-174.

Research output: Contribution to journalArticle

@article{4458f3cc7ddf4fa6b0b12d1d2706e23b,
title = "Experimental measurements and theoretical prediction for the transient characteristic of a two-phase two-component direct contact condenser",
abstract = "The transient characteristics of a three-phase direct contact condenser have been investigated experimentally, utilising a short Perspex column with 48 cm active height and 4 cm internal diameter, and theoretically. Two immiscible fluids, namely pentane vapour with varied initial temperature (41.5 °C, 43.5 °C and47.5 °C) and constant temperature (19 °C) tap water were exploited as the dispersed and the continuous phases respectively. A theoretical model to predict the continuous phase outlet temperature has been developed and solved numerically using MATLAB. The time dependent temperature distribution along the direct contact column was measured and the effect of the mass flow rate ratio and the initial dispersed phase temperature was studied. The experimental results showed that the continuous phase temperatures along the direct contact column increase with time. In addition, no significant effect of the dispersed phase initial temperature on the outlet temperature of the continuous phase was observed. This means that latent heat is dominant in such a direct contact process. Good agreement is achieved between the present theoretical model and the experimental data.",
keywords = "Direct contact condenser, Heat transfer, Transient temperature",
author = "Mahood, {Hameed B.} and Thorpe, {Rex B.} and Campbell, {Alasdair N.} and Sharif, {Adel O.}",
year = "2015",
month = "5",
day = "30",
doi = "10.1016/j.applthermaleng.2015.04.071",
language = "English",
volume = "87",
pages = "161--174",
journal = "Applied Thermal Engineering",
issn = "1359-4311",
publisher = "Elsevier Limited",

}

TY - JOUR

T1 - Experimental measurements and theoretical prediction for the transient characteristic of a two-phase two-component direct contact condenser

AU - Mahood, Hameed B.

AU - Thorpe, Rex B.

AU - Campbell, Alasdair N.

AU - Sharif, Adel O.

PY - 2015/5/30

Y1 - 2015/5/30

N2 - The transient characteristics of a three-phase direct contact condenser have been investigated experimentally, utilising a short Perspex column with 48 cm active height and 4 cm internal diameter, and theoretically. Two immiscible fluids, namely pentane vapour with varied initial temperature (41.5 °C, 43.5 °C and47.5 °C) and constant temperature (19 °C) tap water were exploited as the dispersed and the continuous phases respectively. A theoretical model to predict the continuous phase outlet temperature has been developed and solved numerically using MATLAB. The time dependent temperature distribution along the direct contact column was measured and the effect of the mass flow rate ratio and the initial dispersed phase temperature was studied. The experimental results showed that the continuous phase temperatures along the direct contact column increase with time. In addition, no significant effect of the dispersed phase initial temperature on the outlet temperature of the continuous phase was observed. This means that latent heat is dominant in such a direct contact process. Good agreement is achieved between the present theoretical model and the experimental data.

AB - The transient characteristics of a three-phase direct contact condenser have been investigated experimentally, utilising a short Perspex column with 48 cm active height and 4 cm internal diameter, and theoretically. Two immiscible fluids, namely pentane vapour with varied initial temperature (41.5 °C, 43.5 °C and47.5 °C) and constant temperature (19 °C) tap water were exploited as the dispersed and the continuous phases respectively. A theoretical model to predict the continuous phase outlet temperature has been developed and solved numerically using MATLAB. The time dependent temperature distribution along the direct contact column was measured and the effect of the mass flow rate ratio and the initial dispersed phase temperature was studied. The experimental results showed that the continuous phase temperatures along the direct contact column increase with time. In addition, no significant effect of the dispersed phase initial temperature on the outlet temperature of the continuous phase was observed. This means that latent heat is dominant in such a direct contact process. Good agreement is achieved between the present theoretical model and the experimental data.

KW - Direct contact condenser

KW - Heat transfer

KW - Transient temperature

UR - http://www.scopus.com/inward/record.url?scp=84930653102&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84930653102&partnerID=8YFLogxK

U2 - 10.1016/j.applthermaleng.2015.04.071

DO - 10.1016/j.applthermaleng.2015.04.071

M3 - Article

VL - 87

SP - 161

EP - 174

JO - Applied Thermal Engineering

JF - Applied Thermal Engineering

SN - 1359-4311

ER -