Experimental limitations in impedance spectroscopy: Part II - Electrode artifacts in three-point measurements on Pt/YSZ

G. Hsieh, T. O. Mason, L. R. Pederson

Research output: Contribution to journalArticle

37 Citations (Scopus)

Abstract

High temperature (570-750°C) three-point impedance measurements on the system Pt/YSZ using a platinum reference electrode exhibited distortions/artifacts due to the voltage divider effect. These distortions could be avoided by using a lower impedance reference electrode (Ag) or employing an instrument with a higher input impedance. A correction procedure was also successful.

Original languageEnglish
Pages (from-to)203-212
Number of pages10
JournalSolid State Ionics
Volume91
Issue number3-4
DOIs
Publication statusPublished - 2 Oct 1996
Externally publishedYes

Fingerprint

yttria-stabilized zirconia
artifacts
Spectroscopy
impedance
Voltage dividers
Electrodes
electrodes
dividers
impedance measurement
Platinum
spectroscopy
platinum
electric potential
Temperature

Keywords

  • Impedance spectroscopy
  • Pt electrode
  • YSZ

ASJC Scopus subject areas

  • Electrochemistry
  • Physical and Theoretical Chemistry
  • Energy Engineering and Power Technology
  • Materials Chemistry
  • Condensed Matter Physics

Cite this

Experimental limitations in impedance spectroscopy : Part II - Electrode artifacts in three-point measurements on Pt/YSZ. / Hsieh, G.; Mason, T. O.; Pederson, L. R.

In: Solid State Ionics, Vol. 91, No. 3-4, 02.10.1996, p. 203-212.

Research output: Contribution to journalArticle

@article{88909c8937e641fa9507dfcae1139d4a,
title = "Experimental limitations in impedance spectroscopy: Part II - Electrode artifacts in three-point measurements on Pt/YSZ",
abstract = "High temperature (570-750°C) three-point impedance measurements on the system Pt/YSZ using a platinum reference electrode exhibited distortions/artifacts due to the voltage divider effect. These distortions could be avoided by using a lower impedance reference electrode (Ag) or employing an instrument with a higher input impedance. A correction procedure was also successful.",
keywords = "Impedance spectroscopy, Pt electrode, YSZ",
author = "G. Hsieh and Mason, {T. O.} and Pederson, {L. R.}",
year = "1996",
month = "10",
day = "2",
doi = "10.1016/S0167-2738(96)00403-1",
language = "English",
volume = "91",
pages = "203--212",
journal = "Solid State Ionics",
issn = "0167-2738",
publisher = "Elsevier",
number = "3-4",

}

TY - JOUR

T1 - Experimental limitations in impedance spectroscopy

T2 - Part II - Electrode artifacts in three-point measurements on Pt/YSZ

AU - Hsieh, G.

AU - Mason, T. O.

AU - Pederson, L. R.

PY - 1996/10/2

Y1 - 1996/10/2

N2 - High temperature (570-750°C) three-point impedance measurements on the system Pt/YSZ using a platinum reference electrode exhibited distortions/artifacts due to the voltage divider effect. These distortions could be avoided by using a lower impedance reference electrode (Ag) or employing an instrument with a higher input impedance. A correction procedure was also successful.

AB - High temperature (570-750°C) three-point impedance measurements on the system Pt/YSZ using a platinum reference electrode exhibited distortions/artifacts due to the voltage divider effect. These distortions could be avoided by using a lower impedance reference electrode (Ag) or employing an instrument with a higher input impedance. A correction procedure was also successful.

KW - Impedance spectroscopy

KW - Pt electrode

KW - YSZ

UR - http://www.scopus.com/inward/record.url?scp=0030566065&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0030566065&partnerID=8YFLogxK

U2 - 10.1016/S0167-2738(96)00403-1

DO - 10.1016/S0167-2738(96)00403-1

M3 - Article

AN - SCOPUS:0030566065

VL - 91

SP - 203

EP - 212

JO - Solid State Ionics

JF - Solid State Ionics

SN - 0167-2738

IS - 3-4

ER -