Effects of surface forces and non-uniform out-of-plane illumination on the accuracy of nPIV velocimetry

Reza Sadr, Anoop Baby, R. Khader

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

The accuracy of nano particle image velocimetry (nPIV) measurement obtained from a traditional cross-correlation data reduction method is investigated. nPIV uses evanescent wave illumination of particle tracers in the wallfluid interface where illumination intensity decays exponentially with distance normal to the wall. Therefore, in a shear flow slower particles near the wall appear brighter and bigger than faster particles further away. Furthermore, the presence of hindered Brownian motion combined with hydrodynamic drag, electrostatic, van der Waals and buoyancy forces affects particle displacement and distribution in the measurement region. The effect of all these factors on the calculated velocity using nPIV images is explored using Monte Carlo simulations of particle movement in this region. Fluid velocimetry results are considered for different shear rates of G O(10 3s 1), inter-acquisition time of Δt O(10 3s) and typical experimental surface forces. The results show that these factors can lead to an underestimation of the measured averaged velocity in this region that is in contrast with the previously reported bias when using particle tracking velocimetry techniques. An experimental nPIV measurement of Poiseuille flow in a micro channel is presented to show this difference and implementation of the results of numerical simulation.

Original languageEnglish
Article number055303
JournalMeasurement Science and Technology
Volume23
Issue number5
DOIs
Publication statusPublished - May 2012

Fingerprint

particle image velocimetry
Velocity measurement
Nanoparticles
Illumination
Lighting
illumination
electrostatic drag
Evanescent Wave
Particle Tracking
Poiseuille Flow
Data Reduction
Microchannel
Van Der Waals
Buoyancy
Shear Flow
Cross-correlation
Reduction Method
Drag
Brownian movement
Electrostatics

Keywords

  • cross-correlation
  • evanescent wave
  • fluid velocimetry
  • microfluidics
  • nPIV
  • PIV

ASJC Scopus subject areas

  • Instrumentation
  • Applied Mathematics

Cite this

@article{4dd8ec318b7847d0b6e321794cbb535e,
title = "Effects of surface forces and non-uniform out-of-plane illumination on the accuracy of nPIV velocimetry",
abstract = "The accuracy of nano particle image velocimetry (nPIV) measurement obtained from a traditional cross-correlation data reduction method is investigated. nPIV uses evanescent wave illumination of particle tracers in the wallfluid interface where illumination intensity decays exponentially with distance normal to the wall. Therefore, in a shear flow slower particles near the wall appear brighter and bigger than faster particles further away. Furthermore, the presence of hindered Brownian motion combined with hydrodynamic drag, electrostatic, van der Waals and buoyancy forces affects particle displacement and distribution in the measurement region. The effect of all these factors on the calculated velocity using nPIV images is explored using Monte Carlo simulations of particle movement in this region. Fluid velocimetry results are considered for different shear rates of G O(10 3s 1), inter-acquisition time of Δt O(10 3s) and typical experimental surface forces. The results show that these factors can lead to an underestimation of the measured averaged velocity in this region that is in contrast with the previously reported bias when using particle tracking velocimetry techniques. An experimental nPIV measurement of Poiseuille flow in a micro channel is presented to show this difference and implementation of the results of numerical simulation.",
keywords = "cross-correlation, evanescent wave, fluid velocimetry, microfluidics, nPIV, PIV",
author = "Reza Sadr and Anoop Baby and R. Khader",
year = "2012",
month = "5",
doi = "10.1088/0957-0233/23/5/055303",
language = "English",
volume = "23",
journal = "Measurement Science and Technology",
issn = "0957-0233",
publisher = "IOP Publishing Ltd.",
number = "5",

}

TY - JOUR

T1 - Effects of surface forces and non-uniform out-of-plane illumination on the accuracy of nPIV velocimetry

AU - Sadr, Reza

AU - Baby, Anoop

AU - Khader, R.

PY - 2012/5

Y1 - 2012/5

N2 - The accuracy of nano particle image velocimetry (nPIV) measurement obtained from a traditional cross-correlation data reduction method is investigated. nPIV uses evanescent wave illumination of particle tracers in the wallfluid interface where illumination intensity decays exponentially with distance normal to the wall. Therefore, in a shear flow slower particles near the wall appear brighter and bigger than faster particles further away. Furthermore, the presence of hindered Brownian motion combined with hydrodynamic drag, electrostatic, van der Waals and buoyancy forces affects particle displacement and distribution in the measurement region. The effect of all these factors on the calculated velocity using nPIV images is explored using Monte Carlo simulations of particle movement in this region. Fluid velocimetry results are considered for different shear rates of G O(10 3s 1), inter-acquisition time of Δt O(10 3s) and typical experimental surface forces. The results show that these factors can lead to an underestimation of the measured averaged velocity in this region that is in contrast with the previously reported bias when using particle tracking velocimetry techniques. An experimental nPIV measurement of Poiseuille flow in a micro channel is presented to show this difference and implementation of the results of numerical simulation.

AB - The accuracy of nano particle image velocimetry (nPIV) measurement obtained from a traditional cross-correlation data reduction method is investigated. nPIV uses evanescent wave illumination of particle tracers in the wallfluid interface where illumination intensity decays exponentially with distance normal to the wall. Therefore, in a shear flow slower particles near the wall appear brighter and bigger than faster particles further away. Furthermore, the presence of hindered Brownian motion combined with hydrodynamic drag, electrostatic, van der Waals and buoyancy forces affects particle displacement and distribution in the measurement region. The effect of all these factors on the calculated velocity using nPIV images is explored using Monte Carlo simulations of particle movement in this region. Fluid velocimetry results are considered for different shear rates of G O(10 3s 1), inter-acquisition time of Δt O(10 3s) and typical experimental surface forces. The results show that these factors can lead to an underestimation of the measured averaged velocity in this region that is in contrast with the previously reported bias when using particle tracking velocimetry techniques. An experimental nPIV measurement of Poiseuille flow in a micro channel is presented to show this difference and implementation of the results of numerical simulation.

KW - cross-correlation

KW - evanescent wave

KW - fluid velocimetry

KW - microfluidics

KW - nPIV

KW - PIV

UR - http://www.scopus.com/inward/record.url?scp=84859882796&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84859882796&partnerID=8YFLogxK

U2 - 10.1088/0957-0233/23/5/055303

DO - 10.1088/0957-0233/23/5/055303

M3 - Article

VL - 23

JO - Measurement Science and Technology

JF - Measurement Science and Technology

SN - 0957-0233

IS - 5

M1 - 055303

ER -