Abstract

This paper studies the effect of stator winding configuration on the performance of five-phase induction machines under healthy as well as faulty conditions. The study compares two connections, namely, star and pentagon connections. The comparison is conducted using both simulation and experimental results. The steady-state model based on symmetrical components theory is introduced for both connections with one-line open due to a converter fault, and the corresponding machine characteristic curves are estimated. During faults, two alternatives for machine operation are possible, namely, open-loop control and optimal current control. While the first alternative corresponds to higher torque ripple and unbalanced winding currents, the second option necessitates unbalanced phase voltages and typically an increased dc-link voltage to source the required optimal currents. Consequently, an increase in the employed semiconductor device rating is required, which is a critical design factor particularly in medium-voltage applications. A new V/f control technique is proposed to ensure disturbance-free operation with one-line open for both winding connections. Based on the unbalanced machine model and experimental verification, the derating factors that ensure safe machine operation for both winding connection alternatives are calculated. The comparison between the two connections shows the superiority of the pentagon connection under fault conditions in terms of efficiency, average torque, torque ripples, and derating factor.

Original languageEnglish
Article number6419810
Pages (from-to)3-19
Number of pages17
JournalIEEE Transactions on Industrial Electronics
Volume61
Issue number1
DOIs
Publication statusPublished - 2014

Fingerprint

Stators
Torque
Electric potential
Electric current control
Semiconductor devices
Stars

Keywords

  • Derating factors
  • Dynamic model
  • Fault tolerant
  • Induction machine (IM)
  • Multiphase machine
  • Open-loop control
  • Optimal current control
  • Pentagon connection
  • Stator winding configuration
  • Steady-state model

ASJC Scopus subject areas

  • Control and Systems Engineering
  • Computer Science Applications
  • Electrical and Electronic Engineering

Cite this

Effect of stator winding connection on performance of five-phase induction machines. / Abdel-Khalik, Ayman; Morsy, Ahmed S.; Ahmed, Shehab; Massoud, Ahmed M.

In: IEEE Transactions on Industrial Electronics, Vol. 61, No. 1, 6419810, 2014, p. 3-19.

Research output: Contribution to journalArticle

@article{1fae3646a18c46c4a38d41b5e3210d09,
title = "Effect of stator winding connection on performance of five-phase induction machines",
abstract = "This paper studies the effect of stator winding configuration on the performance of five-phase induction machines under healthy as well as faulty conditions. The study compares two connections, namely, star and pentagon connections. The comparison is conducted using both simulation and experimental results. The steady-state model based on symmetrical components theory is introduced for both connections with one-line open due to a converter fault, and the corresponding machine characteristic curves are estimated. During faults, two alternatives for machine operation are possible, namely, open-loop control and optimal current control. While the first alternative corresponds to higher torque ripple and unbalanced winding currents, the second option necessitates unbalanced phase voltages and typically an increased dc-link voltage to source the required optimal currents. Consequently, an increase in the employed semiconductor device rating is required, which is a critical design factor particularly in medium-voltage applications. A new V/f control technique is proposed to ensure disturbance-free operation with one-line open for both winding connections. Based on the unbalanced machine model and experimental verification, the derating factors that ensure safe machine operation for both winding connection alternatives are calculated. The comparison between the two connections shows the superiority of the pentagon connection under fault conditions in terms of efficiency, average torque, torque ripples, and derating factor.",
keywords = "Derating factors, Dynamic model, Fault tolerant, Induction machine (IM), Multiphase machine, Open-loop control, Optimal current control, Pentagon connection, Stator winding configuration, Steady-state model",
author = "Ayman Abdel-Khalik and Morsy, {Ahmed S.} and Shehab Ahmed and Massoud, {Ahmed M.}",
year = "2014",
doi = "10.1109/TIE.2013.2242417",
language = "English",
volume = "61",
pages = "3--19",
journal = "IEEE Transactions on Industrial Electronics",
issn = "0278-0046",
publisher = "IEEE Industrial Electronics Society",
number = "1",

}

TY - JOUR

T1 - Effect of stator winding connection on performance of five-phase induction machines

AU - Abdel-Khalik, Ayman

AU - Morsy, Ahmed S.

AU - Ahmed, Shehab

AU - Massoud, Ahmed M.

PY - 2014

Y1 - 2014

N2 - This paper studies the effect of stator winding configuration on the performance of five-phase induction machines under healthy as well as faulty conditions. The study compares two connections, namely, star and pentagon connections. The comparison is conducted using both simulation and experimental results. The steady-state model based on symmetrical components theory is introduced for both connections with one-line open due to a converter fault, and the corresponding machine characteristic curves are estimated. During faults, two alternatives for machine operation are possible, namely, open-loop control and optimal current control. While the first alternative corresponds to higher torque ripple and unbalanced winding currents, the second option necessitates unbalanced phase voltages and typically an increased dc-link voltage to source the required optimal currents. Consequently, an increase in the employed semiconductor device rating is required, which is a critical design factor particularly in medium-voltage applications. A new V/f control technique is proposed to ensure disturbance-free operation with one-line open for both winding connections. Based on the unbalanced machine model and experimental verification, the derating factors that ensure safe machine operation for both winding connection alternatives are calculated. The comparison between the two connections shows the superiority of the pentagon connection under fault conditions in terms of efficiency, average torque, torque ripples, and derating factor.

AB - This paper studies the effect of stator winding configuration on the performance of five-phase induction machines under healthy as well as faulty conditions. The study compares two connections, namely, star and pentagon connections. The comparison is conducted using both simulation and experimental results. The steady-state model based on symmetrical components theory is introduced for both connections with one-line open due to a converter fault, and the corresponding machine characteristic curves are estimated. During faults, two alternatives for machine operation are possible, namely, open-loop control and optimal current control. While the first alternative corresponds to higher torque ripple and unbalanced winding currents, the second option necessitates unbalanced phase voltages and typically an increased dc-link voltage to source the required optimal currents. Consequently, an increase in the employed semiconductor device rating is required, which is a critical design factor particularly in medium-voltage applications. A new V/f control technique is proposed to ensure disturbance-free operation with one-line open for both winding connections. Based on the unbalanced machine model and experimental verification, the derating factors that ensure safe machine operation for both winding connection alternatives are calculated. The comparison between the two connections shows the superiority of the pentagon connection under fault conditions in terms of efficiency, average torque, torque ripples, and derating factor.

KW - Derating factors

KW - Dynamic model

KW - Fault tolerant

KW - Induction machine (IM)

KW - Multiphase machine

KW - Open-loop control

KW - Optimal current control

KW - Pentagon connection

KW - Stator winding configuration

KW - Steady-state model

UR - http://www.scopus.com/inward/record.url?scp=84880871085&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84880871085&partnerID=8YFLogxK

U2 - 10.1109/TIE.2013.2242417

DO - 10.1109/TIE.2013.2242417

M3 - Article

AN - SCOPUS:84880871085

VL - 61

SP - 3

EP - 19

JO - IEEE Transactions on Industrial Electronics

JF - IEEE Transactions on Industrial Electronics

SN - 0278-0046

IS - 1

M1 - 6419810

ER -