Differentiation between nerve and adipose tissue using wide-band (350-1,830 nm) in vivo diffuse reflectance spectroscopy

Rutger M. Schols, Mark Ter Laan, Laurents P.S. Stassen, Nicole D. Bouvy, Arjen Amelink, Fokko P. Wieringa, Lejla Alic

Research output: Contribution to journalArticle

10 Citations (Scopus)

Abstract

Background Intraoperative nerve localization is of great importance in surgery. In certain procedures, where nerves show visual resemblance to surrounding adipose tissue, this can be particularly challenging for the human eye. An example of such a delicate procedure is thyroid and parathyroid surgery, where iatrogenic injury of the recurrent laryngeal nerve can result in transient or permanent vocal problems (0.5-2.0% reported incidence). A camera system, enabling nerve-specific image enhancement, would be useful in preventing such complications. This might be realized with hyperspectral camera technology using silicon (Si) or indium gallium arsenide (InGaAs) sensor chips. Methods As a first step towards such a camera, we evaluated the performance of diffuse reflectance spectroscopy by analysing spectra collected during 18 thyroid and parathyroid resections. We assessed the contrast information present in two different spectral ranges, for respectively Si and InGaAs sensors. Two hundred fifty three in vivo, wide-band diffuse reflectance spectra (350-1,830 nm range, 1 nm resolution) were acquired on 52 tissue spots, including nerve (n = 22), muscle (n = 12), and adipose tissue (n = 18). We extracted 36 features from these spectroscopic data: 18 gradients and 18 amplitude differences at predefined points in the tissue spectra. Best distinctive feature combinations were established using binary logistic regression. Classification performance was evaluated in a cross-validation (CV) approach by leave-one-out (LOO). To generalize nerve recognition applicability, we performed a train-test (TT) validation using the thyroid and parathyroid surgery data for training purposes and carpal tunnel release surgery data (10 nerve spots and 5 adipose spots) for classification purposes. Results For combinations of two distinctive spectral features, LOO revealed an accuracy of respectively 78% for Si-sensors and 95% for InGaAs-sensors. TT revealed accuracies of respectively 67% and 100%. Conclusions Using diffuse reflectance spectroscopy we have identified that InGaAs sensors are better suited for automated discrimination between nerves and surrounding adipose tissue than Si sensors.

Original languageEnglish
Pages (from-to)538-545
Number of pages8
JournalLasers in Surgery and Medicine
Volume46
Issue number7
DOIs
Publication statusPublished - 1 Jan 2014
Externally publishedYes

Fingerprint

Nerve Tissue
Silicon
Adipose Tissue
Spectrum Analysis
Thyroid Gland
Recurrent Laryngeal Nerve Injuries
Image Enhancement
Wrist
Logistic Models
Technology
Muscles
gallium arsenide
indium arsenide
Incidence

Keywords

  • adipose tissue
  • automated nerve detection
  • diffuse reflectance spectroscopy
  • median nerve
  • recurrent laryngeal nerve
  • tissue spectral analysis

ASJC Scopus subject areas

  • Surgery
  • Dermatology

Cite this

Differentiation between nerve and adipose tissue using wide-band (350-1,830 nm) in vivo diffuse reflectance spectroscopy. / Schols, Rutger M.; Ter Laan, Mark; Stassen, Laurents P.S.; Bouvy, Nicole D.; Amelink, Arjen; Wieringa, Fokko P.; Alic, Lejla.

In: Lasers in Surgery and Medicine, Vol. 46, No. 7, 01.01.2014, p. 538-545.

Research output: Contribution to journalArticle

Schols, Rutger M. ; Ter Laan, Mark ; Stassen, Laurents P.S. ; Bouvy, Nicole D. ; Amelink, Arjen ; Wieringa, Fokko P. ; Alic, Lejla. / Differentiation between nerve and adipose tissue using wide-band (350-1,830 nm) in vivo diffuse reflectance spectroscopy. In: Lasers in Surgery and Medicine. 2014 ; Vol. 46, No. 7. pp. 538-545.
@article{f545bb3eb1414fb9a01e4390b5ea93a0,
title = "Differentiation between nerve and adipose tissue using wide-band (350-1,830 nm) in vivo diffuse reflectance spectroscopy",
abstract = "Background Intraoperative nerve localization is of great importance in surgery. In certain procedures, where nerves show visual resemblance to surrounding adipose tissue, this can be particularly challenging for the human eye. An example of such a delicate procedure is thyroid and parathyroid surgery, where iatrogenic injury of the recurrent laryngeal nerve can result in transient or permanent vocal problems (0.5-2.0{\%} reported incidence). A camera system, enabling nerve-specific image enhancement, would be useful in preventing such complications. This might be realized with hyperspectral camera technology using silicon (Si) or indium gallium arsenide (InGaAs) sensor chips. Methods As a first step towards such a camera, we evaluated the performance of diffuse reflectance spectroscopy by analysing spectra collected during 18 thyroid and parathyroid resections. We assessed the contrast information present in two different spectral ranges, for respectively Si and InGaAs sensors. Two hundred fifty three in vivo, wide-band diffuse reflectance spectra (350-1,830 nm range, 1 nm resolution) were acquired on 52 tissue spots, including nerve (n = 22), muscle (n = 12), and adipose tissue (n = 18). We extracted 36 features from these spectroscopic data: 18 gradients and 18 amplitude differences at predefined points in the tissue spectra. Best distinctive feature combinations were established using binary logistic regression. Classification performance was evaluated in a cross-validation (CV) approach by leave-one-out (LOO). To generalize nerve recognition applicability, we performed a train-test (TT) validation using the thyroid and parathyroid surgery data for training purposes and carpal tunnel release surgery data (10 nerve spots and 5 adipose spots) for classification purposes. Results For combinations of two distinctive spectral features, LOO revealed an accuracy of respectively 78{\%} for Si-sensors and 95{\%} for InGaAs-sensors. TT revealed accuracies of respectively 67{\%} and 100{\%}. Conclusions Using diffuse reflectance spectroscopy we have identified that InGaAs sensors are better suited for automated discrimination between nerves and surrounding adipose tissue than Si sensors.",
keywords = "adipose tissue, automated nerve detection, diffuse reflectance spectroscopy, median nerve, recurrent laryngeal nerve, tissue spectral analysis",
author = "Schols, {Rutger M.} and {Ter Laan}, Mark and Stassen, {Laurents P.S.} and Bouvy, {Nicole D.} and Arjen Amelink and Wieringa, {Fokko P.} and Lejla Alic",
year = "2014",
month = "1",
day = "1",
doi = "10.1002/lsm.22264",
language = "English",
volume = "46",
pages = "538--545",
journal = "Lasers in Surgery and Medicine",
issn = "0196-8092",
publisher = "Wiley-Liss Inc.",
number = "7",

}

TY - JOUR

T1 - Differentiation between nerve and adipose tissue using wide-band (350-1,830 nm) in vivo diffuse reflectance spectroscopy

AU - Schols, Rutger M.

AU - Ter Laan, Mark

AU - Stassen, Laurents P.S.

AU - Bouvy, Nicole D.

AU - Amelink, Arjen

AU - Wieringa, Fokko P.

AU - Alic, Lejla

PY - 2014/1/1

Y1 - 2014/1/1

N2 - Background Intraoperative nerve localization is of great importance in surgery. In certain procedures, where nerves show visual resemblance to surrounding adipose tissue, this can be particularly challenging for the human eye. An example of such a delicate procedure is thyroid and parathyroid surgery, where iatrogenic injury of the recurrent laryngeal nerve can result in transient or permanent vocal problems (0.5-2.0% reported incidence). A camera system, enabling nerve-specific image enhancement, would be useful in preventing such complications. This might be realized with hyperspectral camera technology using silicon (Si) or indium gallium arsenide (InGaAs) sensor chips. Methods As a first step towards such a camera, we evaluated the performance of diffuse reflectance spectroscopy by analysing spectra collected during 18 thyroid and parathyroid resections. We assessed the contrast information present in two different spectral ranges, for respectively Si and InGaAs sensors. Two hundred fifty three in vivo, wide-band diffuse reflectance spectra (350-1,830 nm range, 1 nm resolution) were acquired on 52 tissue spots, including nerve (n = 22), muscle (n = 12), and adipose tissue (n = 18). We extracted 36 features from these spectroscopic data: 18 gradients and 18 amplitude differences at predefined points in the tissue spectra. Best distinctive feature combinations were established using binary logistic regression. Classification performance was evaluated in a cross-validation (CV) approach by leave-one-out (LOO). To generalize nerve recognition applicability, we performed a train-test (TT) validation using the thyroid and parathyroid surgery data for training purposes and carpal tunnel release surgery data (10 nerve spots and 5 adipose spots) for classification purposes. Results For combinations of two distinctive spectral features, LOO revealed an accuracy of respectively 78% for Si-sensors and 95% for InGaAs-sensors. TT revealed accuracies of respectively 67% and 100%. Conclusions Using diffuse reflectance spectroscopy we have identified that InGaAs sensors are better suited for automated discrimination between nerves and surrounding adipose tissue than Si sensors.

AB - Background Intraoperative nerve localization is of great importance in surgery. In certain procedures, where nerves show visual resemblance to surrounding adipose tissue, this can be particularly challenging for the human eye. An example of such a delicate procedure is thyroid and parathyroid surgery, where iatrogenic injury of the recurrent laryngeal nerve can result in transient or permanent vocal problems (0.5-2.0% reported incidence). A camera system, enabling nerve-specific image enhancement, would be useful in preventing such complications. This might be realized with hyperspectral camera technology using silicon (Si) or indium gallium arsenide (InGaAs) sensor chips. Methods As a first step towards such a camera, we evaluated the performance of diffuse reflectance spectroscopy by analysing spectra collected during 18 thyroid and parathyroid resections. We assessed the contrast information present in two different spectral ranges, for respectively Si and InGaAs sensors. Two hundred fifty three in vivo, wide-band diffuse reflectance spectra (350-1,830 nm range, 1 nm resolution) were acquired on 52 tissue spots, including nerve (n = 22), muscle (n = 12), and adipose tissue (n = 18). We extracted 36 features from these spectroscopic data: 18 gradients and 18 amplitude differences at predefined points in the tissue spectra. Best distinctive feature combinations were established using binary logistic regression. Classification performance was evaluated in a cross-validation (CV) approach by leave-one-out (LOO). To generalize nerve recognition applicability, we performed a train-test (TT) validation using the thyroid and parathyroid surgery data for training purposes and carpal tunnel release surgery data (10 nerve spots and 5 adipose spots) for classification purposes. Results For combinations of two distinctive spectral features, LOO revealed an accuracy of respectively 78% for Si-sensors and 95% for InGaAs-sensors. TT revealed accuracies of respectively 67% and 100%. Conclusions Using diffuse reflectance spectroscopy we have identified that InGaAs sensors are better suited for automated discrimination between nerves and surrounding adipose tissue than Si sensors.

KW - adipose tissue

KW - automated nerve detection

KW - diffuse reflectance spectroscopy

KW - median nerve

KW - recurrent laryngeal nerve

KW - tissue spectral analysis

UR - http://www.scopus.com/inward/record.url?scp=84906352263&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84906352263&partnerID=8YFLogxK

U2 - 10.1002/lsm.22264

DO - 10.1002/lsm.22264

M3 - Article

VL - 46

SP - 538

EP - 545

JO - Lasers in Surgery and Medicine

JF - Lasers in Surgery and Medicine

SN - 0196-8092

IS - 7

ER -