Cooling effectiveness of shaped film holes for leading edge

Tarek Elnady, Ibrahim Hassan, Lyse Kadem, Terry Lucas

Research output: Contribution to journalArticle

11 Citations (Scopus)

Abstract

An experimental investigation has been carried out to improve the film cooling performance at the leading edge of a gas turbine vane. The standard cylindrical holes, located on the stagnation line, are modified with two expansion levels at the hole exit, 2d and 4d. A two-dimensional cascade has been employed to measure the cooling effectiveness of the two expansion levels and the standard hole using the transient Thermochromatic Liquid Crystal technique. The air is injected at 90 o and 60 o inclination angle relative to the vane surface with four blowing ratios ranging from 1 to 2 at a 0.9 density ratio. The Mach number and the Reynolds number of the main stream based on the cascade exit velocity and the axial chord are 0.23 and 1.4E5, respectively. The detailed local cooling effectiveness downstream the film holes over both the pressure side and the suction side are presented in addition to the lateral-averaged cooling effectiveness. The proposed expansion enhances the coolant distribution over the leading edge, particularly toward the suction side. The effectiveness increases toward the pressure side as well, yielding uniform thermal stresses around the stagnation line. The cooling effectiveness improved with increasing blowing ratio due to the jet lift-off reduction, hence higher cooling capacity is provided.

Original languageEnglish
Pages (from-to)649-661
Number of pages13
JournalExperimental Thermal and Fluid Science
Volume44
DOIs
Publication statusPublished - Jan 2013
Externally publishedYes

Fingerprint

Cooling
Blow molding
Liquid Crystals
Thermal stress
Coolants
Liquid crystals
Mach number
Gas turbines
Reynolds number
Air

Keywords

  • Cooling effectiveness
  • Film cooling
  • Gas turbine
  • Leading edge
  • TLC

ASJC Scopus subject areas

  • Fluid Flow and Transfer Processes
  • Mechanical Engineering
  • Chemical Engineering(all)
  • Aerospace Engineering
  • Nuclear Energy and Engineering

Cite this

Cooling effectiveness of shaped film holes for leading edge. / Elnady, Tarek; Hassan, Ibrahim; Kadem, Lyse; Lucas, Terry.

In: Experimental Thermal and Fluid Science, Vol. 44, 01.2013, p. 649-661.

Research output: Contribution to journalArticle

Elnady, Tarek ; Hassan, Ibrahim ; Kadem, Lyse ; Lucas, Terry. / Cooling effectiveness of shaped film holes for leading edge. In: Experimental Thermal and Fluid Science. 2013 ; Vol. 44. pp. 649-661.
@article{00988b41dad44e49b7e94f4a8c9c5a3c,
title = "Cooling effectiveness of shaped film holes for leading edge",
abstract = "An experimental investigation has been carried out to improve the film cooling performance at the leading edge of a gas turbine vane. The standard cylindrical holes, located on the stagnation line, are modified with two expansion levels at the hole exit, 2d and 4d. A two-dimensional cascade has been employed to measure the cooling effectiveness of the two expansion levels and the standard hole using the transient Thermochromatic Liquid Crystal technique. The air is injected at 90 o and 60 o inclination angle relative to the vane surface with four blowing ratios ranging from 1 to 2 at a 0.9 density ratio. The Mach number and the Reynolds number of the main stream based on the cascade exit velocity and the axial chord are 0.23 and 1.4E5, respectively. The detailed local cooling effectiveness downstream the film holes over both the pressure side and the suction side are presented in addition to the lateral-averaged cooling effectiveness. The proposed expansion enhances the coolant distribution over the leading edge, particularly toward the suction side. The effectiveness increases toward the pressure side as well, yielding uniform thermal stresses around the stagnation line. The cooling effectiveness improved with increasing blowing ratio due to the jet lift-off reduction, hence higher cooling capacity is provided.",
keywords = "Cooling effectiveness, Film cooling, Gas turbine, Leading edge, TLC",
author = "Tarek Elnady and Ibrahim Hassan and Lyse Kadem and Terry Lucas",
year = "2013",
month = "1",
doi = "10.1016/j.expthermflusci.2012.09.005",
language = "English",
volume = "44",
pages = "649--661",
journal = "Experimental Thermal and Fluid Science",
issn = "0894-1777",
publisher = "Elsevier Inc.",

}

TY - JOUR

T1 - Cooling effectiveness of shaped film holes for leading edge

AU - Elnady, Tarek

AU - Hassan, Ibrahim

AU - Kadem, Lyse

AU - Lucas, Terry

PY - 2013/1

Y1 - 2013/1

N2 - An experimental investigation has been carried out to improve the film cooling performance at the leading edge of a gas turbine vane. The standard cylindrical holes, located on the stagnation line, are modified with two expansion levels at the hole exit, 2d and 4d. A two-dimensional cascade has been employed to measure the cooling effectiveness of the two expansion levels and the standard hole using the transient Thermochromatic Liquid Crystal technique. The air is injected at 90 o and 60 o inclination angle relative to the vane surface with four blowing ratios ranging from 1 to 2 at a 0.9 density ratio. The Mach number and the Reynolds number of the main stream based on the cascade exit velocity and the axial chord are 0.23 and 1.4E5, respectively. The detailed local cooling effectiveness downstream the film holes over both the pressure side and the suction side are presented in addition to the lateral-averaged cooling effectiveness. The proposed expansion enhances the coolant distribution over the leading edge, particularly toward the suction side. The effectiveness increases toward the pressure side as well, yielding uniform thermal stresses around the stagnation line. The cooling effectiveness improved with increasing blowing ratio due to the jet lift-off reduction, hence higher cooling capacity is provided.

AB - An experimental investigation has been carried out to improve the film cooling performance at the leading edge of a gas turbine vane. The standard cylindrical holes, located on the stagnation line, are modified with two expansion levels at the hole exit, 2d and 4d. A two-dimensional cascade has been employed to measure the cooling effectiveness of the two expansion levels and the standard hole using the transient Thermochromatic Liquid Crystal technique. The air is injected at 90 o and 60 o inclination angle relative to the vane surface with four blowing ratios ranging from 1 to 2 at a 0.9 density ratio. The Mach number and the Reynolds number of the main stream based on the cascade exit velocity and the axial chord are 0.23 and 1.4E5, respectively. The detailed local cooling effectiveness downstream the film holes over both the pressure side and the suction side are presented in addition to the lateral-averaged cooling effectiveness. The proposed expansion enhances the coolant distribution over the leading edge, particularly toward the suction side. The effectiveness increases toward the pressure side as well, yielding uniform thermal stresses around the stagnation line. The cooling effectiveness improved with increasing blowing ratio due to the jet lift-off reduction, hence higher cooling capacity is provided.

KW - Cooling effectiveness

KW - Film cooling

KW - Gas turbine

KW - Leading edge

KW - TLC

UR - http://www.scopus.com/inward/record.url?scp=84869172871&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84869172871&partnerID=8YFLogxK

U2 - 10.1016/j.expthermflusci.2012.09.005

DO - 10.1016/j.expthermflusci.2012.09.005

M3 - Article

AN - SCOPUS:84869172871

VL - 44

SP - 649

EP - 661

JO - Experimental Thermal and Fluid Science

JF - Experimental Thermal and Fluid Science

SN - 0894-1777

ER -