Cooling effectiveness of shaped film holes for leading edge

Tarek Elnady, Ibrahim Hassan, Lyse Kadem, Terry Lucas

Research output: Contribution to journalArticle

11 Citations (Scopus)

Abstract

An experimental investigation has been carried out to improve the film cooling performance at the leading edge of a gas turbine vane. The standard cylindrical holes, located on the stagnation line, are modified with two expansion levels at the hole exit, 2d and 4d. A two-dimensional cascade has been employed to measure the cooling effectiveness of the two expansion levels and the standard hole using the transient Thermochromatic Liquid Crystal technique. The air is injected at 90 o and 60 o inclination angle relative to the vane surface with four blowing ratios ranging from 1 to 2 at a 0.9 density ratio. The Mach number and the Reynolds number of the main stream based on the cascade exit velocity and the axial chord are 0.23 and 1.4E5, respectively. The detailed local cooling effectiveness downstream the film holes over both the pressure side and the suction side are presented in addition to the lateral-averaged cooling effectiveness. The proposed expansion enhances the coolant distribution over the leading edge, particularly toward the suction side. The effectiveness increases toward the pressure side as well, yielding uniform thermal stresses around the stagnation line. The cooling effectiveness improved with increasing blowing ratio due to the jet lift-off reduction, hence higher cooling capacity is provided.

Original languageEnglish
Pages (from-to)649-661
Number of pages13
JournalExperimental Thermal and Fluid Science
Volume44
DOIs
Publication statusPublished - Jan 2013
Externally publishedYes

    Fingerprint

Keywords

  • Cooling effectiveness
  • Film cooling
  • Gas turbine
  • Leading edge
  • TLC

ASJC Scopus subject areas

  • Fluid Flow and Transfer Processes
  • Mechanical Engineering
  • Chemical Engineering(all)
  • Aerospace Engineering
  • Nuclear Energy and Engineering

Cite this