Cardiac electrophysiological imaging systems scalable for high-throughput drug testing

Peter Lee, Ken Wang, Christopher E. Woods, Ping Yan, Peter Kohl, Paul Ewart, Leslie M. Loew, Derek A. Terrar, Christian Bollensdorff

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

Multi-parametric electrophysiological measurements using optical methods have become a highly valued standard in cardiac research. Most published optical mapping systems are expensive and complex. Although some applications demand high-cost components and complex designs, many can be tackled with simpler solutions. Here, we describe (1) a camera-based voltage and calcium imaging system using a single 'economy' electron-multiplying charge-coupled device camera and demonstrate the possibility of using a consumer camera for imaging calcium transients of the heart, and (2) a photodiode-based voltage and calcium high temporal resolution measurement system using single-element photodiodes and an optical fibre. High-throughput drug testing represents an application where system scalability is particularly attractive. Therefore, we tested our systems on tissue exposed to a well-characterized and clinically relevant calcium channel blocker, nifedipine, which has been used to treat angina and hypertension. As experimental models, we used the Langendorff-perfused whole-heart and thin ventricular tissue slices, a preparation gaining renewed interest by the cardiac research community. Using our simplified systems, we were able to monitor simultaneously the marked changes in the voltage and calcium transients that are responsible for the negative inotropic effect of the compound.

Original languageEnglish
Pages (from-to)645-656
Number of pages12
JournalPflugers Archiv European Journal of Physiology
Volume464
Issue number6
DOIs
Publication statusPublished - 1 Dec 2012
Externally publishedYes

Fingerprint

Imaging systems
Throughput
Calcium
Testing
Photodiodes
Pharmaceutical Preparations
Electric potential
Cameras
Tissue
Optical Fibers
Optical Devices
Calcium Channel Blockers
Nifedipine
CCD cameras
Research
Scalability
Optical fibers
Theoretical Models
Electrons
Hypertension

Keywords

  • Cardiac
  • Drug testing
  • Fluorescence
  • High-speed imaging
  • Highthroughput
  • Multi-parametric
  • Optical mapping
  • Voltage and calcium-sensitive dyes

ASJC Scopus subject areas

  • Physiology
  • Clinical Biochemistry
  • Physiology (medical)

Cite this

Cardiac electrophysiological imaging systems scalable for high-throughput drug testing. / Lee, Peter; Wang, Ken; Woods, Christopher E.; Yan, Ping; Kohl, Peter; Ewart, Paul; Loew, Leslie M.; Terrar, Derek A.; Bollensdorff, Christian.

In: Pflugers Archiv European Journal of Physiology, Vol. 464, No. 6, 01.12.2012, p. 645-656.

Research output: Contribution to journalArticle

Lee, P, Wang, K, Woods, CE, Yan, P, Kohl, P, Ewart, P, Loew, LM, Terrar, DA & Bollensdorff, C 2012, 'Cardiac electrophysiological imaging systems scalable for high-throughput drug testing', Pflugers Archiv European Journal of Physiology, vol. 464, no. 6, pp. 645-656. https://doi.org/10.1007/s00424-012-1149-0
Lee, Peter ; Wang, Ken ; Woods, Christopher E. ; Yan, Ping ; Kohl, Peter ; Ewart, Paul ; Loew, Leslie M. ; Terrar, Derek A. ; Bollensdorff, Christian. / Cardiac electrophysiological imaging systems scalable for high-throughput drug testing. In: Pflugers Archiv European Journal of Physiology. 2012 ; Vol. 464, No. 6. pp. 645-656.
@article{6d81ca5ae7bf49f6a7727c42b9fe7f91,
title = "Cardiac electrophysiological imaging systems scalable for high-throughput drug testing",
abstract = "Multi-parametric electrophysiological measurements using optical methods have become a highly valued standard in cardiac research. Most published optical mapping systems are expensive and complex. Although some applications demand high-cost components and complex designs, many can be tackled with simpler solutions. Here, we describe (1) a camera-based voltage and calcium imaging system using a single 'economy' electron-multiplying charge-coupled device camera and demonstrate the possibility of using a consumer camera for imaging calcium transients of the heart, and (2) a photodiode-based voltage and calcium high temporal resolution measurement system using single-element photodiodes and an optical fibre. High-throughput drug testing represents an application where system scalability is particularly attractive. Therefore, we tested our systems on tissue exposed to a well-characterized and clinically relevant calcium channel blocker, nifedipine, which has been used to treat angina and hypertension. As experimental models, we used the Langendorff-perfused whole-heart and thin ventricular tissue slices, a preparation gaining renewed interest by the cardiac research community. Using our simplified systems, we were able to monitor simultaneously the marked changes in the voltage and calcium transients that are responsible for the negative inotropic effect of the compound.",
keywords = "Cardiac, Drug testing, Fluorescence, High-speed imaging, Highthroughput, Multi-parametric, Optical mapping, Voltage and calcium-sensitive dyes",
author = "Peter Lee and Ken Wang and Woods, {Christopher E.} and Ping Yan and Peter Kohl and Paul Ewart and Loew, {Leslie M.} and Terrar, {Derek A.} and Christian Bollensdorff",
year = "2012",
month = "12",
day = "1",
doi = "10.1007/s00424-012-1149-0",
language = "English",
volume = "464",
pages = "645--656",
journal = "Pflugers Archiv European Journal of Physiology",
issn = "0031-6768",
publisher = "Springer Verlag",
number = "6",

}

TY - JOUR

T1 - Cardiac electrophysiological imaging systems scalable for high-throughput drug testing

AU - Lee, Peter

AU - Wang, Ken

AU - Woods, Christopher E.

AU - Yan, Ping

AU - Kohl, Peter

AU - Ewart, Paul

AU - Loew, Leslie M.

AU - Terrar, Derek A.

AU - Bollensdorff, Christian

PY - 2012/12/1

Y1 - 2012/12/1

N2 - Multi-parametric electrophysiological measurements using optical methods have become a highly valued standard in cardiac research. Most published optical mapping systems are expensive and complex. Although some applications demand high-cost components and complex designs, many can be tackled with simpler solutions. Here, we describe (1) a camera-based voltage and calcium imaging system using a single 'economy' electron-multiplying charge-coupled device camera and demonstrate the possibility of using a consumer camera for imaging calcium transients of the heart, and (2) a photodiode-based voltage and calcium high temporal resolution measurement system using single-element photodiodes and an optical fibre. High-throughput drug testing represents an application where system scalability is particularly attractive. Therefore, we tested our systems on tissue exposed to a well-characterized and clinically relevant calcium channel blocker, nifedipine, which has been used to treat angina and hypertension. As experimental models, we used the Langendorff-perfused whole-heart and thin ventricular tissue slices, a preparation gaining renewed interest by the cardiac research community. Using our simplified systems, we were able to monitor simultaneously the marked changes in the voltage and calcium transients that are responsible for the negative inotropic effect of the compound.

AB - Multi-parametric electrophysiological measurements using optical methods have become a highly valued standard in cardiac research. Most published optical mapping systems are expensive and complex. Although some applications demand high-cost components and complex designs, many can be tackled with simpler solutions. Here, we describe (1) a camera-based voltage and calcium imaging system using a single 'economy' electron-multiplying charge-coupled device camera and demonstrate the possibility of using a consumer camera for imaging calcium transients of the heart, and (2) a photodiode-based voltage and calcium high temporal resolution measurement system using single-element photodiodes and an optical fibre. High-throughput drug testing represents an application where system scalability is particularly attractive. Therefore, we tested our systems on tissue exposed to a well-characterized and clinically relevant calcium channel blocker, nifedipine, which has been used to treat angina and hypertension. As experimental models, we used the Langendorff-perfused whole-heart and thin ventricular tissue slices, a preparation gaining renewed interest by the cardiac research community. Using our simplified systems, we were able to monitor simultaneously the marked changes in the voltage and calcium transients that are responsible for the negative inotropic effect of the compound.

KW - Cardiac

KW - Drug testing

KW - Fluorescence

KW - High-speed imaging

KW - Highthroughput

KW - Multi-parametric

KW - Optical mapping

KW - Voltage and calcium-sensitive dyes

UR - http://www.scopus.com/inward/record.url?scp=84873740658&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84873740658&partnerID=8YFLogxK

U2 - 10.1007/s00424-012-1149-0

DO - 10.1007/s00424-012-1149-0

M3 - Article

VL - 464

SP - 645

EP - 656

JO - Pflugers Archiv European Journal of Physiology

JF - Pflugers Archiv European Journal of Physiology

SN - 0031-6768

IS - 6

ER -