A simple active-power control technique for grid-connected three-phase inverters at unity power factor

A. Elserougi, Ayman Abdel-Khalik, Shehab Ahmed, A. Massoud

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

This paper presents a simple active-power control technique for low voltage grid-connected three-phase inverters with zero injected reactive power (unity power factor at grid). Two versions of the proposed controller are introduced, namely, open-loop and closed loop controllers. The proposed controller is characterized by lower computational burden and reduced number of sensors, which are desired features for low-cost systems. The performance of the proposed controllers is studied during normal as well as abnormal operating conditions.

Original languageEnglish
Title of host publicationProceedings of 2013 4th International Conference on Power Engineering, Energy and Electrical Drives, POWERENG 2013
Pages265-270
Number of pages6
DOIs
Publication statusPublished - 2013
Externally publishedYes
Event2013 4th International Conference on Power Engineering, Energy and Electrical Drives, POWERENG 2013 - Istanbul, Turkey
Duration: 13 May 201317 May 2013

Other

Other2013 4th International Conference on Power Engineering, Energy and Electrical Drives, POWERENG 2013
CountryTurkey
CityIstanbul
Period13/5/1317/5/13

Fingerprint

Power control
Controllers
Reactive power
Sensors
Electric potential
Costs

Keywords

  • boost inverter
  • distributed power
  • grid connected inverters
  • unity power factor

ASJC Scopus subject areas

  • Energy Engineering and Power Technology
  • Nuclear Energy and Engineering
  • Renewable Energy, Sustainability and the Environment

Cite this

Elserougi, A., Abdel-Khalik, A., Ahmed, S., & Massoud, A. (2013). A simple active-power control technique for grid-connected three-phase inverters at unity power factor. In Proceedings of 2013 4th International Conference on Power Engineering, Energy and Electrical Drives, POWERENG 2013 (pp. 265-270). [6635617] https://doi.org/10.1109/PowerEng.2013.6635617

A simple active-power control technique for grid-connected three-phase inverters at unity power factor. / Elserougi, A.; Abdel-Khalik, Ayman; Ahmed, Shehab; Massoud, A.

Proceedings of 2013 4th International Conference on Power Engineering, Energy and Electrical Drives, POWERENG 2013. 2013. p. 265-270 6635617.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Elserougi, A, Abdel-Khalik, A, Ahmed, S & Massoud, A 2013, A simple active-power control technique for grid-connected three-phase inverters at unity power factor. in Proceedings of 2013 4th International Conference on Power Engineering, Energy and Electrical Drives, POWERENG 2013., 6635617, pp. 265-270, 2013 4th International Conference on Power Engineering, Energy and Electrical Drives, POWERENG 2013, Istanbul, Turkey, 13/5/13. https://doi.org/10.1109/PowerEng.2013.6635617
Elserougi A, Abdel-Khalik A, Ahmed S, Massoud A. A simple active-power control technique for grid-connected three-phase inverters at unity power factor. In Proceedings of 2013 4th International Conference on Power Engineering, Energy and Electrical Drives, POWERENG 2013. 2013. p. 265-270. 6635617 https://doi.org/10.1109/PowerEng.2013.6635617
Elserougi, A. ; Abdel-Khalik, Ayman ; Ahmed, Shehab ; Massoud, A. / A simple active-power control technique for grid-connected three-phase inverters at unity power factor. Proceedings of 2013 4th International Conference on Power Engineering, Energy and Electrical Drives, POWERENG 2013. 2013. pp. 265-270
@inproceedings{b13cb3afcbd54e118eaaa4a87013241e,
title = "A simple active-power control technique for grid-connected three-phase inverters at unity power factor",
abstract = "This paper presents a simple active-power control technique for low voltage grid-connected three-phase inverters with zero injected reactive power (unity power factor at grid). Two versions of the proposed controller are introduced, namely, open-loop and closed loop controllers. The proposed controller is characterized by lower computational burden and reduced number of sensors, which are desired features for low-cost systems. The performance of the proposed controllers is studied during normal as well as abnormal operating conditions.",
keywords = "boost inverter, distributed power, grid connected inverters, unity power factor",
author = "A. Elserougi and Ayman Abdel-Khalik and Shehab Ahmed and A. Massoud",
year = "2013",
doi = "10.1109/PowerEng.2013.6635617",
language = "English",
isbn = "9781467363921",
pages = "265--270",
booktitle = "Proceedings of 2013 4th International Conference on Power Engineering, Energy and Electrical Drives, POWERENG 2013",

}

TY - GEN

T1 - A simple active-power control technique for grid-connected three-phase inverters at unity power factor

AU - Elserougi, A.

AU - Abdel-Khalik, Ayman

AU - Ahmed, Shehab

AU - Massoud, A.

PY - 2013

Y1 - 2013

N2 - This paper presents a simple active-power control technique for low voltage grid-connected three-phase inverters with zero injected reactive power (unity power factor at grid). Two versions of the proposed controller are introduced, namely, open-loop and closed loop controllers. The proposed controller is characterized by lower computational burden and reduced number of sensors, which are desired features for low-cost systems. The performance of the proposed controllers is studied during normal as well as abnormal operating conditions.

AB - This paper presents a simple active-power control technique for low voltage grid-connected three-phase inverters with zero injected reactive power (unity power factor at grid). Two versions of the proposed controller are introduced, namely, open-loop and closed loop controllers. The proposed controller is characterized by lower computational burden and reduced number of sensors, which are desired features for low-cost systems. The performance of the proposed controllers is studied during normal as well as abnormal operating conditions.

KW - boost inverter

KW - distributed power

KW - grid connected inverters

KW - unity power factor

UR - http://www.scopus.com/inward/record.url?scp=84887372926&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84887372926&partnerID=8YFLogxK

U2 - 10.1109/PowerEng.2013.6635617

DO - 10.1109/PowerEng.2013.6635617

M3 - Conference contribution

SN - 9781467363921

SP - 265

EP - 270

BT - Proceedings of 2013 4th International Conference on Power Engineering, Energy and Electrical Drives, POWERENG 2013

ER -