Abstract

This paper presents a robust gas identification technique for tin oxide (SnO2) gas sensors. The proposed technique generates a unique spike pattern or signature for each sensed gas, irrespective of its concentration. The proposed gas identification technique is insensitive to drift in the sensor baseline resistance. Furthermore, its calibration requires a single measurement to be made for each targeted gas. The proposed spike-based gas identification technique has been implemented in TSMC 0.18μm CMOS technology and validated using experimental data from a fabricated in-house 4x4 SnO2gas sensor array. Reported results reveal a 10% increase in correct gas detection rate.

Original languageEnglish
Title of host publication2009 IEEE International Symposium on Circuits and Systems, ISCAS 2009
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages553-556
Number of pages4
ISBN (Print)9781424438280
DOIs
Publication statusPublished - 2009
Externally publishedYes
Event2009 IEEE International Symposium on Circuits and Systems, ISCAS 2009 - Taipei, Taiwan, Province of China
Duration: 24 May 200927 May 2009

Other

Other2009 IEEE International Symposium on Circuits and Systems, ISCAS 2009
CountryTaiwan, Province of China
CityTaipei
Period24/5/0927/5/09

Fingerprint

Sensors
Gases
Sensor arrays
Tin oxides
Chemical sensors
Calibration

ASJC Scopus subject areas

  • Electrical and Electronic Engineering

Cite this

Ng, K. T., Chen, H. T., Boussaid, F., Bermak, A., & Martinez, D. (2009). A robust spike-based gas identification technique for SnO2gas sensors. In 2009 IEEE International Symposium on Circuits and Systems, ISCAS 2009 (pp. 553-556). [5117808] Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/ISCAS.2009.5117808

A robust spike-based gas identification technique for SnO2gas sensors. / Ng, Kwan Ting; Chen, Hung Tat; Boussaid, Farid; Bermak, Amine; Martinez, Dominique.

2009 IEEE International Symposium on Circuits and Systems, ISCAS 2009. Institute of Electrical and Electronics Engineers Inc., 2009. p. 553-556 5117808.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Ng, KT, Chen, HT, Boussaid, F, Bermak, A & Martinez, D 2009, A robust spike-based gas identification technique for SnO2gas sensors. in 2009 IEEE International Symposium on Circuits and Systems, ISCAS 2009., 5117808, Institute of Electrical and Electronics Engineers Inc., pp. 553-556, 2009 IEEE International Symposium on Circuits and Systems, ISCAS 2009, Taipei, Taiwan, Province of China, 24/5/09. https://doi.org/10.1109/ISCAS.2009.5117808
Ng KT, Chen HT, Boussaid F, Bermak A, Martinez D. A robust spike-based gas identification technique for SnO2gas sensors. In 2009 IEEE International Symposium on Circuits and Systems, ISCAS 2009. Institute of Electrical and Electronics Engineers Inc. 2009. p. 553-556. 5117808 https://doi.org/10.1109/ISCAS.2009.5117808
Ng, Kwan Ting ; Chen, Hung Tat ; Boussaid, Farid ; Bermak, Amine ; Martinez, Dominique. / A robust spike-based gas identification technique for SnO2gas sensors. 2009 IEEE International Symposium on Circuits and Systems, ISCAS 2009. Institute of Electrical and Electronics Engineers Inc., 2009. pp. 553-556
@inproceedings{1a1414df8c4c48228189171c5e4bb521,
title = "A robust spike-based gas identification technique for SnO2gas sensors",
abstract = "This paper presents a robust gas identification technique for tin oxide (SnO2) gas sensors. The proposed technique generates a unique spike pattern or signature for each sensed gas, irrespective of its concentration. The proposed gas identification technique is insensitive to drift in the sensor baseline resistance. Furthermore, its calibration requires a single measurement to be made for each targeted gas. The proposed spike-based gas identification technique has been implemented in TSMC 0.18μm CMOS technology and validated using experimental data from a fabricated in-house 4x4 SnO2gas sensor array. Reported results reveal a 10{\%} increase in correct gas detection rate.",
author = "Ng, {Kwan Ting} and Chen, {Hung Tat} and Farid Boussaid and Amine Bermak and Dominique Martinez",
year = "2009",
doi = "10.1109/ISCAS.2009.5117808",
language = "English",
isbn = "9781424438280",
pages = "553--556",
booktitle = "2009 IEEE International Symposium on Circuits and Systems, ISCAS 2009",
publisher = "Institute of Electrical and Electronics Engineers Inc.",

}

TY - GEN

T1 - A robust spike-based gas identification technique for SnO2gas sensors

AU - Ng, Kwan Ting

AU - Chen, Hung Tat

AU - Boussaid, Farid

AU - Bermak, Amine

AU - Martinez, Dominique

PY - 2009

Y1 - 2009

N2 - This paper presents a robust gas identification technique for tin oxide (SnO2) gas sensors. The proposed technique generates a unique spike pattern or signature for each sensed gas, irrespective of its concentration. The proposed gas identification technique is insensitive to drift in the sensor baseline resistance. Furthermore, its calibration requires a single measurement to be made for each targeted gas. The proposed spike-based gas identification technique has been implemented in TSMC 0.18μm CMOS technology and validated using experimental data from a fabricated in-house 4x4 SnO2gas sensor array. Reported results reveal a 10% increase in correct gas detection rate.

AB - This paper presents a robust gas identification technique for tin oxide (SnO2) gas sensors. The proposed technique generates a unique spike pattern or signature for each sensed gas, irrespective of its concentration. The proposed gas identification technique is insensitive to drift in the sensor baseline resistance. Furthermore, its calibration requires a single measurement to be made for each targeted gas. The proposed spike-based gas identification technique has been implemented in TSMC 0.18μm CMOS technology and validated using experimental data from a fabricated in-house 4x4 SnO2gas sensor array. Reported results reveal a 10% increase in correct gas detection rate.

UR - http://www.scopus.com/inward/record.url?scp=70350141746&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=70350141746&partnerID=8YFLogxK

U2 - 10.1109/ISCAS.2009.5117808

DO - 10.1109/ISCAS.2009.5117808

M3 - Conference contribution

AN - SCOPUS:70350141746

SN - 9781424438280

SP - 553

EP - 556

BT - 2009 IEEE International Symposium on Circuits and Systems, ISCAS 2009

PB - Institute of Electrical and Electronics Engineers Inc.

ER -