A method for intensity calibration of an electron spectrometer with multi-angle detection

Levente Ábrók, Ticia Buhr, Ákos Kövér, Robert Balog, Dávid Hatvani, Péter Herczku, Sándor Kovács, Sándor Ricz

Research output: Contribution to journalArticle

Abstract

A special electrostatic electron spectrometer designed for precise and unique experiments and an intensity calibration method for universal application in electron spectroscopy are presented. The upgrade of the analyzer enables the intensity calibration at arbitrary electron energies using elastically scattered electrons. In order to test the calibration procedure the double differential (in energy and angle) ionization cross sections (DDCS) of electrons ejected from 300 keV proton-argon collisions were measured and compared with the data of Rudd et al. [1]. The good agreement between the two data sets verifies the applicability of the calibration method.

Original languageEnglish
Pages (from-to)24-28
Number of pages5
JournalNuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms
Volume369
DOIs
Publication statusPublished - 15 Feb 2016
Externally publishedYes

Fingerprint

Spectrometers
Calibration
spectrometers
Electrons
electrons
ionization cross sections
electron spectroscopy
Electron spectroscopy
analyzers
argon
electron energy
electrostatics
Ionization
Argon
Electrostatics
Protons
collisions
protons
energy
Experiments

Keywords

  • Atom
  • Collision
  • Electron spectroscopy
  • Photoelectron
  • Photon

ASJC Scopus subject areas

  • Nuclear and High Energy Physics
  • Instrumentation

Cite this

A method for intensity calibration of an electron spectrometer with multi-angle detection. / Ábrók, Levente; Buhr, Ticia; Kövér, Ákos; Balog, Robert; Hatvani, Dávid; Herczku, Péter; Kovács, Sándor; Ricz, Sándor.

In: Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, Vol. 369, 15.02.2016, p. 24-28.

Research output: Contribution to journalArticle

Ábrók, Levente ; Buhr, Ticia ; Kövér, Ákos ; Balog, Robert ; Hatvani, Dávid ; Herczku, Péter ; Kovács, Sándor ; Ricz, Sándor. / A method for intensity calibration of an electron spectrometer with multi-angle detection. In: Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms. 2016 ; Vol. 369. pp. 24-28.
@article{70375778734c4b659f7e863f8fca7e58,
title = "A method for intensity calibration of an electron spectrometer with multi-angle detection",
abstract = "A special electrostatic electron spectrometer designed for precise and unique experiments and an intensity calibration method for universal application in electron spectroscopy are presented. The upgrade of the analyzer enables the intensity calibration at arbitrary electron energies using elastically scattered electrons. In order to test the calibration procedure the double differential (in energy and angle) ionization cross sections (DDCS) of electrons ejected from 300 keV proton-argon collisions were measured and compared with the data of Rudd et al. [1]. The good agreement between the two data sets verifies the applicability of the calibration method.",
keywords = "Atom, Collision, Electron spectroscopy, Photoelectron, Photon",
author = "Levente {\'A}br{\'o}k and Ticia Buhr and {\'A}kos K{\"o}v{\'e}r and Robert Balog and D{\'a}vid Hatvani and P{\'e}ter Herczku and S{\'a}ndor Kov{\'a}cs and S{\'a}ndor Ricz",
year = "2016",
month = "2",
day = "15",
doi = "10.1016/j.nimb.2015.10.037",
language = "English",
volume = "369",
pages = "24--28",
journal = "Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms",
issn = "0168-583X",
publisher = "Elsevier",

}

TY - JOUR

T1 - A method for intensity calibration of an electron spectrometer with multi-angle detection

AU - Ábrók, Levente

AU - Buhr, Ticia

AU - Kövér, Ákos

AU - Balog, Robert

AU - Hatvani, Dávid

AU - Herczku, Péter

AU - Kovács, Sándor

AU - Ricz, Sándor

PY - 2016/2/15

Y1 - 2016/2/15

N2 - A special electrostatic electron spectrometer designed for precise and unique experiments and an intensity calibration method for universal application in electron spectroscopy are presented. The upgrade of the analyzer enables the intensity calibration at arbitrary electron energies using elastically scattered electrons. In order to test the calibration procedure the double differential (in energy and angle) ionization cross sections (DDCS) of electrons ejected from 300 keV proton-argon collisions were measured and compared with the data of Rudd et al. [1]. The good agreement between the two data sets verifies the applicability of the calibration method.

AB - A special electrostatic electron spectrometer designed for precise and unique experiments and an intensity calibration method for universal application in electron spectroscopy are presented. The upgrade of the analyzer enables the intensity calibration at arbitrary electron energies using elastically scattered electrons. In order to test the calibration procedure the double differential (in energy and angle) ionization cross sections (DDCS) of electrons ejected from 300 keV proton-argon collisions were measured and compared with the data of Rudd et al. [1]. The good agreement between the two data sets verifies the applicability of the calibration method.

KW - Atom

KW - Collision

KW - Electron spectroscopy

KW - Photoelectron

KW - Photon

UR - http://www.scopus.com/inward/record.url?scp=84957436552&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84957436552&partnerID=8YFLogxK

U2 - 10.1016/j.nimb.2015.10.037

DO - 10.1016/j.nimb.2015.10.037

M3 - Article

VL - 369

SP - 24

EP - 28

JO - Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms

JF - Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms

SN - 0168-583X

ER -